Information extraction from Murphy-Good plots of tungsten field electron emitters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F21%3APU145841" target="_blank" >RIV/00216305:26620/21:PU145841 - isvavai.cz</a>
Výsledek na webu
<a href="https://avs.scitation.org/doi/10.1116/6.0000803" target="_blank" >https://avs.scitation.org/doi/10.1116/6.0000803</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1116/6.0000803" target="_blank" >10.1116/6.0000803</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Information extraction from Murphy-Good plots of tungsten field electron emitters
Popis výsledku v původním jazyce
This study introduces an easy methodology to test and analyze experimental field electron emission current-voltage data from metallic single-tip emitters; this novel and easy methodology is called the Murphy-Good plots. Tungsten electron emitters were used as an example and were prepared by the electrochemical etching process. The current-voltage characteristics are obtained in high vacuum levels and using a traditional field emission microscope. Murphy-Good plots are used to apply the well-known field electron emission orthodoxy test to the experimental data and then to extract the emitters' characterization parameters if the test is passed. The novelty in using this type of plots lies in its independency on any correction factors, unlike the traditional Fowler-Nordheim and Millikan-Lauritsen plots, in addition to its simple theoretical form. The results are calculated using a simple web tool that applies the field electron emission orthodoxy test to any type of the current-voltage analysis plots and then to extract the characterization parameters of the emitters.
Název v anglickém jazyce
Information extraction from Murphy-Good plots of tungsten field electron emitters
Popis výsledku anglicky
This study introduces an easy methodology to test and analyze experimental field electron emission current-voltage data from metallic single-tip emitters; this novel and easy methodology is called the Murphy-Good plots. Tungsten electron emitters were used as an example and were prepared by the electrochemical etching process. The current-voltage characteristics are obtained in high vacuum levels and using a traditional field emission microscope. Murphy-Good plots are used to apply the well-known field electron emission orthodoxy test to the experimental data and then to extract the emitters' characterization parameters if the test is passed. The novelty in using this type of plots lies in its independency on any correction factors, unlike the traditional Fowler-Nordheim and Millikan-Lauritsen plots, in addition to its simple theoretical form. The results are calculated using a simple web tool that applies the field electron emission orthodoxy test to any type of the current-voltage analysis plots and then to extract the characterization parameters of the emitters.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018110" target="_blank" >LM2018110: Výzkumná infrastruktura CzechNanoLab</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B
ISSN
2166-2746
e-ISSN
—
Svazek periodika
39
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
000629878900001
EID výsledku v databázi Scopus
2-s2.0-85100591825