A mid-infrared lab-on-a-chip for dynamic reaction monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F22%3APU147100" target="_blank" >RIV/00216305:26620/22:PU147100 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.nature.com/articles/s41467-022-32417-7" target="_blank" >https://www.nature.com/articles/s41467-022-32417-7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41467-022-32417-7" target="_blank" >10.1038/s41467-022-32417-7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A mid-infrared lab-on-a-chip for dynamic reaction monitoring
Popis výsledku v původním jazyce
Mid-infrared spectroscopy is a sensitive and selective technique for probing molecules in the gas or liquid phase. Investigating chemical reactions in bio-medical applications such as drug production is recently gaining particular interest. However, monitoring dynamic processes in liquids is commonly limited to bulky systems and thus requires time-consuming offline analytics. In this work, we show a next-generation, fully-integrated and robust chip-scale sensor for online measurements of molecule dynamics in a liquid solution. Our fingertip-sized device utilizes quantum cascade technology, combining the emitter, sensing section and detector on a single chip. This enables real-time measurements probing only microliter amounts of analyte in an in situ configuration. We demonstrate time-resolved device operation by analyzing temperature-induced conformational changes of the model protein bovine serum albumin in heavy water. Quantitative measurements reveal excellent performance characteristics in terms of sensor linearity, wide coverage of concentrations, extending from 0.075 mg ml(-1) to 92 mg ml(-1) and a 55-times higher absorbance than state-of-the-art bulky and offline reference systems. Rapid investigation of chemical reactions is a challenge in bio-medical analysis. Here, the authors demonstrate sensitive in-situ real-time reaction-monitoring of conformational changes in protein solution, based on a fingertip-sized mid-IR lab-on-a-chip.
Název v anglickém jazyce
A mid-infrared lab-on-a-chip for dynamic reaction monitoring
Popis výsledku anglicky
Mid-infrared spectroscopy is a sensitive and selective technique for probing molecules in the gas or liquid phase. Investigating chemical reactions in bio-medical applications such as drug production is recently gaining particular interest. However, monitoring dynamic processes in liquids is commonly limited to bulky systems and thus requires time-consuming offline analytics. In this work, we show a next-generation, fully-integrated and robust chip-scale sensor for online measurements of molecule dynamics in a liquid solution. Our fingertip-sized device utilizes quantum cascade technology, combining the emitter, sensing section and detector on a single chip. This enables real-time measurements probing only microliter amounts of analyte in an in situ configuration. We demonstrate time-resolved device operation by analyzing temperature-induced conformational changes of the model protein bovine serum albumin in heavy water. Quantitative measurements reveal excellent performance characteristics in terms of sensor linearity, wide coverage of concentrations, extending from 0.075 mg ml(-1) to 92 mg ml(-1) and a 55-times higher absorbance than state-of-the-art bulky and offline reference systems. Rapid investigation of chemical reactions is a challenge in bio-medical analysis. Here, the authors demonstrate sensitive in-situ real-time reaction-monitoring of conformational changes in protein solution, based on a fingertip-sized mid-IR lab-on-a-chip.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10700 - Other natural sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018110" target="_blank" >LM2018110: Výzkumná infrastruktura CzechNanoLab</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
NATURE COMMUNICATIONS
ISSN
2041-1723
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
„“-„“
Kód UT WoS článku
000840338100013
EID výsledku v databázi Scopus
2-s2.0-85135946654