Fatigue behaviour of titanium scaffolds with hierarchical porosity produced by material extrusion additive manufacturing

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F23%3APU146573" target="_blank" >RIV/00216305:26620/23:PU146573 - isvavai.cz</a>

  • Výsledek na webu

    <a href="https://www.sciencedirect.com/science/article/pii/S0264127522010760" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0264127522010760</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.matdes.2022.111453" target="_blank" >10.1016/j.matdes.2022.111453</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Fatigue behaviour of titanium scaffolds with hierarchical porosity produced by material extrusion additive manufacturing

  • Popis výsledku v původním jazyce

    Metallic porous structures (scaffolds) produced by additive manufacturing represent an important class of personalised implants used in load-bearing orthopaedic applications. As such, their fatigue performance must be excellent to prevent the need for revision surgery. This paper provides insight into the high-cycle fatigue behaviour of novel titanium scaffolds with hierarchical porosity and properties comparable to those of human bone that were produced by direct ink writing (DIW) and tested under cyclic loading typical for bone implants. Opposite to traditional expectations in the field of metal fatigue, scaffolds produced with an open intrastrand pore network (14.3%) endured nearly an order of magnitude more cycles than those with relatively compact strands (5.9%) and their normalized fatigue strength (62% of their yield strength in one milion cycles) was competitive with many current titanium scaffolds produced by other additive manufacturing technologies. Improved fatigue performance was related to fatigue crack growth shielding effects that reduced the crack growth rate, prolonged the crack path, and increased energy absorption. Consequently, these novel hierarchically porous titanium structures prepared by DIW can serve safely under cyclic loading conditions, and at the same time can provide multiple open porosity-related functionalities in advanced biomedicine and other industrial sectors.

  • Název v anglickém jazyce

    Fatigue behaviour of titanium scaffolds with hierarchical porosity produced by material extrusion additive manufacturing

  • Popis výsledku anglicky

    Metallic porous structures (scaffolds) produced by additive manufacturing represent an important class of personalised implants used in load-bearing orthopaedic applications. As such, their fatigue performance must be excellent to prevent the need for revision surgery. This paper provides insight into the high-cycle fatigue behaviour of novel titanium scaffolds with hierarchical porosity and properties comparable to those of human bone that were produced by direct ink writing (DIW) and tested under cyclic loading typical for bone implants. Opposite to traditional expectations in the field of metal fatigue, scaffolds produced with an open intrastrand pore network (14.3%) endured nearly an order of magnitude more cycles than those with relatively compact strands (5.9%) and their normalized fatigue strength (62% of their yield strength in one milion cycles) was competitive with many current titanium scaffolds produced by other additive manufacturing technologies. Improved fatigue performance was related to fatigue crack growth shielding effects that reduced the crack growth rate, prolonged the crack path, and increased energy absorption. Consequently, these novel hierarchically porous titanium structures prepared by DIW can serve safely under cyclic loading conditions, and at the same time can provide multiple open porosity-related functionalities in advanced biomedicine and other industrial sectors.

Klasifikace

  • Druh

    J<sub>imp</sub> - Článek v periodiku v databázi Web of Science

  • CEP obor

  • OECD FORD obor

    20501 - Materials engineering

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/LTAIN19112" target="_blank" >LTAIN19112: Vývoj vysokopevnostních porézních titanových struktur vyznačujících se nízkým modulem pružnosti spolu s bioaktivními a antibakteriálními vlastnostmi pro implantáty v ortopedii</a><br>

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Ostatní

  • Rok uplatnění

    2023

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Materials & Design

  • ISSN

    0264-1275

  • e-ISSN

    1873-4197

  • Svazek periodika

    225

  • Číslo periodika v rámci svazku

    1

  • Stát vydavatele periodika

    GB - Spojené království Velké Británie a Severního Irska

  • Počet stran výsledku

    11

  • Strana od-do

    1-11

  • Kód UT WoS článku

    000908055300009

  • EID výsledku v databázi Scopus