Bone Response to Biodegradable Metals and In Vitro Evaluation of the Cytocompatibility
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F26%3A0197800" target="_blank" >RIV/00216305:26620/26:0197800 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s11837-025-07353-8" target="_blank" >https://link.springer.com/article/10.1007/s11837-025-07353-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11837-025-07353-8" target="_blank" >10.1007/s11837-025-07353-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bone Response to Biodegradable Metals and In Vitro Evaluation of the Cytocompatibility
Popis výsledku v původním jazyce
This review focuses on the bone response to biodegradable metals used in temporary osteosynthesis devices. These implants are designed to degrade in vivo, fully dissolving after stabilizing fractures, osteotomies, and ligament fixations, thus eliminating the need for a second surgery. The review delves into the interactions between biodegradable metallic implants and bone tissue, emphasizing the bidirectional nature of this process. It covers the families of biodegradable metals and their degradation mechanisms, with particular attention paid to the time-dependence of the foreign body reaction and the local sterile inflammation response. Additionally, the review discusses current in vitro methods for evaluating biological safety, osteogenic properties, and inflammatory responses. The limitations of traditional cell culture models in replicating the in vivo bone environment are discussed, along with recent advancements in the field. The review concludes by proposing strategies to control the degradation of biodegradable metals and more accurately replicate bone tissue, which could potentially enable more precise in vitro degradation and biological characterization, reducing reliance on in vivo experiments.
Název v anglickém jazyce
Bone Response to Biodegradable Metals and In Vitro Evaluation of the Cytocompatibility
Popis výsledku anglicky
This review focuses on the bone response to biodegradable metals used in temporary osteosynthesis devices. These implants are designed to degrade in vivo, fully dissolving after stabilizing fractures, osteotomies, and ligament fixations, thus eliminating the need for a second surgery. The review delves into the interactions between biodegradable metallic implants and bone tissue, emphasizing the bidirectional nature of this process. It covers the families of biodegradable metals and their degradation mechanisms, with particular attention paid to the time-dependence of the foreign body reaction and the local sterile inflammation response. Additionally, the review discusses current in vitro methods for evaluating biological safety, osteogenic properties, and inflammatory responses. The limitations of traditional cell culture models in replicating the in vivo bone environment are discussed, along with recent advancements in the field. The review concludes by proposing strategies to control the degradation of biodegradable metals and more accurately replicate bone tissue, which could potentially enable more precise in vitro degradation and biological characterization, reducing reliance on in vivo experiments.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20500 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOM
ISSN
1047-4838
e-ISSN
1543-1851
Svazek periodika
77
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
20
Strana od-do
4473-4492
Kód UT WoS článku
001470066000001
EID výsledku v databázi Scopus
2-s2.0-105003409557