Resolution in Two-Photon Imaging: A Local Manifestation of Entanglement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F26%3A0199600" target="_blank" >RIV/00216305:26620/26:0199600 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.acs.org/doi/10.1021/acsphotonics.5c01310" target="_blank" >https://pubs.acs.org/doi/10.1021/acsphotonics.5c01310</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acsphotonics.5c01310" target="_blank" >10.1021/acsphotonics.5c01310</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Resolution in Two-Photon Imaging: A Local Manifestation of Entanglement
Popis výsledku v původním jazyce
The resolution of a classical imaging system is limited by diffraction. This limit can be overcome, for example, by implementing various forms of localization microscopy in which the center of a fluorescence distribution is estimated to an accuracy scaling with the square root of the number of detected photons, N . In quantum imaging the object can be illuminated using correlated photon-pairs, leading early work to suggest that a 2 improvement could be obtained as a result of averaging the position of N = 2 events. However, similar to quantum lithography, which relies upon quantum illumination using entangled photon-pairs and two-photon absorption, the minimum resolvable feature size is reduced by a factor of 2, not just 2 . Quantum imaging schemes can also lead to a factor of 2 improvement. By using a similar source of correlated photon-pairs to illuminate an object, a single-photon sensitive camera to detect the photon-pairs, and an image processing algorithm to record and sum the bisector positions of the transmitted photon-pairs, we realize a similar factor of x2 improvement in image resolution, surpassing that of most earlier quantum imaging work.
Název v anglickém jazyce
Resolution in Two-Photon Imaging: A Local Manifestation of Entanglement
Popis výsledku anglicky
The resolution of a classical imaging system is limited by diffraction. This limit can be overcome, for example, by implementing various forms of localization microscopy in which the center of a fluorescence distribution is estimated to an accuracy scaling with the square root of the number of detected photons, N . In quantum imaging the object can be illuminated using correlated photon-pairs, leading early work to suggest that a 2 improvement could be obtained as a result of averaging the position of N = 2 events. However, similar to quantum lithography, which relies upon quantum illumination using entangled photon-pairs and two-photon absorption, the minimum resolvable feature size is reduced by a factor of 2, not just 2 . Quantum imaging schemes can also lead to a factor of 2 improvement. By using a similar source of correlated photon-pairs to illuminate an object, a single-photon sensitive camera to detect the photon-pairs, and an image processing algorithm to record and sum the bisector positions of the transmitted photon-pairs, we realize a similar factor of x2 improvement in image resolution, surpassing that of most earlier quantum imaging work.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA24-12283S" target="_blank" >GA24-12283S: Posílení nekoherentního kvantitativního fázového zobrazování zavedením rekonstrukce trojrozměrného obrazu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ACS Photonics
ISSN
2330-4022
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
5594-5604
Kód UT WoS článku
001582796600001
EID výsledku v databázi Scopus
2-s2.0-105018743090