Vše

Co hledáte?

Vše
Projekty
Výsledky výzkumu
Subjekty

Rychlé hledání

  • Projekty podpořené TA ČR
  • Významné projekty
  • Projekty s nejvyšší státní podporou
  • Aktuálně běžící projekty

Chytré vyhledávání

  • Takto najdu konkrétní +slovo
  • Takto z výsledků -slovo zcela vynechám
  • “Takto můžu najít celou frázi”

Verification of reliability of measurement systems for swimming analysis

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26630%2F21%3APU142449" target="_blank" >RIV/00216305:26630/21:PU142449 - isvavai.cz</a>

  • Nalezeny alternativní kódy

    RIV/61989592:15510/21:73612338

  • Výsledek na webu

    <a href="https://rua.ua.es/dspace/bitstream/10045/113666/1/JHSE_16_Proc2_52.pdf" target="_blank" >https://rua.ua.es/dspace/bitstream/10045/113666/1/JHSE_16_Proc2_52.pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.14198/jhse.2021.16.Proc2.52" target="_blank" >10.14198/jhse.2021.16.Proc2.52</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Verification of reliability of measurement systems for swimming analysis

  • Popis výsledku v původním jazyce

    Sophisticated technologies and measuring devices are increasingly being used for the analysis of performance and swimming techniques. At BUT, the Tachograph II and Swimming Inertial Measure Unit (SwIMU) measuring systems were developed for swimming analysis. To evaluate the measured data, the SwimDataViewer software was developed for both measuring systems. To verify the reliability of the Tachograph, 34 race swimmers were measured (15 F, 19 M), and 28 race swimmers (16 M, 12 F) were measured with SwIMU. All swimmers swam a 6x25m front crawl. Pullout and the first three and last two strokes of the arms were not included in the data evaluation. The intraclass correlation coefficient (ICC) was used to verify the reliability of the monitored parameters. The values of measured parameters in the front crawl for Tachograph (SwIMU) were ICC = 0.992 (0.991) for the average value of speed, ICC = 0.958 (0.960) for efficiency, ICC = 0.971 (0.988) for the frequency of the arms, and finally, ICC = 0.978 (0.992) for the frequency of the legs. The ICC coefficient for all monitored parameters in both devices showed a high degree of reliability. From this perspective, both devices are suitable for use in coaching and research practice.

  • Název v anglickém jazyce

    Verification of reliability of measurement systems for swimming analysis

  • Popis výsledku anglicky

    Sophisticated technologies and measuring devices are increasingly being used for the analysis of performance and swimming techniques. At BUT, the Tachograph II and Swimming Inertial Measure Unit (SwIMU) measuring systems were developed for swimming analysis. To evaluate the measured data, the SwimDataViewer software was developed for both measuring systems. To verify the reliability of the Tachograph, 34 race swimmers were measured (15 F, 19 M), and 28 race swimmers (16 M, 12 F) were measured with SwIMU. All swimmers swam a 6x25m front crawl. Pullout and the first three and last two strokes of the arms were not included in the data evaluation. The intraclass correlation coefficient (ICC) was used to verify the reliability of the monitored parameters. The values of measured parameters in the front crawl for Tachograph (SwIMU) were ICC = 0.992 (0.991) for the average value of speed, ICC = 0.958 (0.960) for efficiency, ICC = 0.971 (0.988) for the frequency of the arms, and finally, ICC = 0.978 (0.992) for the frequency of the legs. The ICC coefficient for all monitored parameters in both devices showed a high degree of reliability. From this perspective, both devices are suitable for use in coaching and research practice.

Klasifikace

  • Druh

    J<sub>imp</sub> - Článek v periodiku v databázi Web of Science

  • CEP obor

  • OECD FORD obor

    30306 - Sport and fitness sciences

Návaznosti výsledku

  • Projekt

  • Návaznosti

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Ostatní

  • Rok uplatnění

    2021

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Journal of Human Sport and Exercise

  • ISSN

    1988-5202

  • e-ISSN

  • Svazek periodika

    16

  • Číslo periodika v rámci svazku

    2

  • Stát vydavatele periodika

    ES - Španělské království

  • Počet stran výsledku

    7

  • Strana od-do

    „S671“-„S677“

  • Kód UT WoS článku

    000681300500052

  • EID výsledku v databázi Scopus

    2-s2.0-85114730450