Quantification of liver microcirculation using X-ray microtomography of vascular corrosion casts
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F14%3A10189391" target="_blank" >RIV/00669806:_____/14:10189391 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/14:10189391
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.592-593.505" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.592-593.505</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.592-593.505" target="_blank" >10.4028/www.scientific.net/KEM.592-593.505</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantification of liver microcirculation using X-ray microtomography of vascular corrosion casts
Popis výsledku v původním jazyce
We used corrosion casts and micro-CT for quantitative description of microvascular network in porcine liver. Using stereological methods, manual tracing of microvessels and analysis of orientation in 3D, we quantified the volume fraction, the surface density, the numerical density, the length density and the tortuosity of microvessels in series of images with 1.875 µm pixel resolution. Biodur E 20 resin was more suitable forpreparing and quantifying microvascular tree corrosion casts when compared to Mercox II resin. Quantified data could be applicable for correlating 3D models with 2D liver histopathology, for enhancing the interpretation of routine medical CT and for providing data for computer models of tissue perfusion and angiogenesis.
Název v anglickém jazyce
Quantification of liver microcirculation using X-ray microtomography of vascular corrosion casts
Popis výsledku anglicky
We used corrosion casts and micro-CT for quantitative description of microvascular network in porcine liver. Using stereological methods, manual tracing of microvessels and analysis of orientation in 3D, we quantified the volume fraction, the surface density, the numerical density, the length density and the tortuosity of microvessels in series of images with 1.875 µm pixel resolution. Biodur E 20 resin was more suitable forpreparing and quantifying microvascular tree corrosion casts when compared to Mercox II resin. Quantified data could be applicable for correlating 3D models with 2D liver histopathology, for enhancing the interpretation of routine medical CT and for providing data for computer models of tissue perfusion and angiogenesis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30106 - Anatomy and morphology (plant science to be 1.6)
Návaznosti výsledku
Projekt
<a href="/cs/project/NT13326" target="_blank" >NT13326: Zvyšování resekability maligních ložiskových procesů pomocí metod zpřesňujících měření perfúzních parametrů zbytkového jaterního parenchymu - počítačem asistované diagnostiky a softwarového modelování</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Key Engineering Materials
ISBN
—
ISSN
1013-9826
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
505-508
Název nakladatele
Trans Tech Publications
Místo vydání
Switzerland
Místo konání akce
Brno
Datum konání akce
1. 7. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000336694400113