VEILND (Video Endoscopic Inguinal Lymph Node Dissection) with Florescence Indocyanine Green (ICG): A Novel Technique to Identify the Sentinel Lymph Node in Men with >= pT1G2 and cN0 Penile Cancer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F21%3A10437204" target="_blank" >RIV/00669806:_____/21:10437204 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/21:10437204
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=hISkpuVMaS" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=hISkpuVMaS</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2021/5575730" target="_blank" >10.1155/2021/5575730</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
VEILND (Video Endoscopic Inguinal Lymph Node Dissection) with Florescence Indocyanine Green (ICG): A Novel Technique to Identify the Sentinel Lymph Node in Men with >= pT1G2 and cN0 Penile Cancer
Popis výsledku v původním jazyce
Introduction. In men with >=pT1G2 cN0, penile cancer lymph node sampling is recommended with either (1) scintigraphically labelled Dynamic sentinel lymph node biopsy (DSLNB) or (2) modified inguinal lymph node dissection (MILND). Although DSLNB is a minimally invasive technique, the false negative rate can be about 10%, and a further operative procedure is required if positive. Open MILND is a diagnostic and therapeutic option but has a much higher morbidity. A potential compromise is the technique of LND-VEILND (video endoscopic inguinal LND) that can be combined with ICG florescence marking of sentinel lymph node (SLN). We present a pilot study of ICG-VEILND. The aim was to validate the applicability of a combination ICG marking of SLN in VEILND (to increase probability to excise SLN) and determine the optimal timing and dosage of ICG. Materials and Methods. 15 patients with VEILND (24 groins) underwent ICG application with fluorescence near-infrared (NIR 803LEFTWARDS ARROW 830 nm) detection. ICG is applied subcutaneously adjacent to the penile cancer or residual stump of penis or suprapubic region (in a history of total penectomy: 5 cases). The dose of 1.25 mg (ICG) was applied in one case with invisible SLN, the dose of 2.5 mg in 1 mL in 8 cases, and 5 mg in the remaining 6 patients (10 groins). Results. Failure of marking SLN with ICG occurred in 25.0% of cases (6/24): due to application of 1.25 mg ICG, extensive metastasis to SLN, in 4 cases, the cause was unknown (16.7%, 4/24). In the short follow-up period, no local recurrence was seen in the pN0 ICG group. Conclusion. Fluorescence infrared image with ICG dye increases the probability of removal of the SLN during VEILND. The dose of ICG is 2.5 (5) mg diluted in 1 ml and can be applied preoperatively even in the suprapubic region in men with a history of total penectomy, with an unexplainable failure of ICG marking in 16.7%. (C) 2021 Milan Hora et al.
Název v anglickém jazyce
VEILND (Video Endoscopic Inguinal Lymph Node Dissection) with Florescence Indocyanine Green (ICG): A Novel Technique to Identify the Sentinel Lymph Node in Men with >= pT1G2 and cN0 Penile Cancer
Popis výsledku anglicky
Introduction. In men with >=pT1G2 cN0, penile cancer lymph node sampling is recommended with either (1) scintigraphically labelled Dynamic sentinel lymph node biopsy (DSLNB) or (2) modified inguinal lymph node dissection (MILND). Although DSLNB is a minimally invasive technique, the false negative rate can be about 10%, and a further operative procedure is required if positive. Open MILND is a diagnostic and therapeutic option but has a much higher morbidity. A potential compromise is the technique of LND-VEILND (video endoscopic inguinal LND) that can be combined with ICG florescence marking of sentinel lymph node (SLN). We present a pilot study of ICG-VEILND. The aim was to validate the applicability of a combination ICG marking of SLN in VEILND (to increase probability to excise SLN) and determine the optimal timing and dosage of ICG. Materials and Methods. 15 patients with VEILND (24 groins) underwent ICG application with fluorescence near-infrared (NIR 803LEFTWARDS ARROW 830 nm) detection. ICG is applied subcutaneously adjacent to the penile cancer or residual stump of penis or suprapubic region (in a history of total penectomy: 5 cases). The dose of 1.25 mg (ICG) was applied in one case with invisible SLN, the dose of 2.5 mg in 1 mL in 8 cases, and 5 mg in the remaining 6 patients (10 groins). Results. Failure of marking SLN with ICG occurred in 25.0% of cases (6/24): due to application of 1.25 mg ICG, extensive metastasis to SLN, in 4 cases, the cause was unknown (16.7%, 4/24). In the short follow-up period, no local recurrence was seen in the pN0 ICG group. Conclusion. Fluorescence infrared image with ICG dye increases the probability of removal of the SLN during VEILND. The dose of ICG is 2.5 (5) mg diluted in 1 ml and can be applied preoperatively even in the suprapubic region in men with a history of total penectomy, with an unexplainable failure of ICG marking in 16.7%. (C) 2021 Milan Hora et al.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30217 - Urology and nephrology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Contrast Media & Molecular Imaging
ISSN
1555-4309
e-ISSN
—
Svazek periodika
2021
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
5575730
Kód UT WoS článku
000792830100001
EID výsledku v databázi Scopus
2-s2.0-85118918374