Is ultra low-dose CT with tin filtration useful for examination of SI joints? Can it replace X-ray in diagnostics of sacroiliitis?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F22%3A10425428" target="_blank" >RIV/00669806:_____/22:10425428 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/22:10425428
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=17PS73aM7g" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=17PS73aM7g</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2021.008" target="_blank" >10.5507/bp.2021.008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Is ultra low-dose CT with tin filtration useful for examination of SI joints? Can it replace X-ray in diagnostics of sacroiliitis?
Popis výsledku v původním jazyce
The first objective of our study was to determine the radiation exposure received by patients during tinfiltrated ultra-low-dose computed tomography (TFULDCT) of sacroiliac joints and to compare those to conventional X-ray doses. For comparison, we added a cohort examined by low-dose CT (LDCT) without tin filtration. The second objective was to compare the results of TFULDCT and X-ray in the detection of sacroiliitis. s. Tin filtration helps to reduce CT radiation exposure to values lower than those resulting from CR. TFULDCT offers better overall diagnostic performance than CR. Our results prove that TFULDCT can replace CR in the diagnosis of sacroiliitis in the radiographical stage of AxSpA
Název v anglickém jazyce
Is ultra low-dose CT with tin filtration useful for examination of SI joints? Can it replace X-ray in diagnostics of sacroiliitis?
Popis výsledku anglicky
The first objective of our study was to determine the radiation exposure received by patients during tinfiltrated ultra-low-dose computed tomography (TFULDCT) of sacroiliac joints and to compare those to conventional X-ray doses. For comparison, we added a cohort examined by low-dose CT (LDCT) without tin filtration. The second objective was to compare the results of TFULDCT and X-ray in the detection of sacroiliitis. s. Tin filtration helps to reduce CT radiation exposure to values lower than those resulting from CR. TFULDCT offers better overall diagnostic performance than CR. Our results prove that TFULDCT can replace CR in the diagnosis of sacroiliitis in the radiographical stage of AxSpA
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_048%2F0007280" target="_blank" >EF17_048/0007280: Aplikace moderních technologií v medicíně a průmyslu</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
1804-7521
Svazek periodika
166
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
77-83
Kód UT WoS článku
000731339000001
EID výsledku v databázi Scopus
2-s2.0-85126490362