Outcome of Continuous Positive Airway Pressure Adherence Based on Nasal Endoscopy and the Measurement of Nasal Patency-A Prospective Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F23%3A10464818" target="_blank" >RIV/00669806:_____/23:10464818 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/23:10464818 RIV/00216208:11150/23:10464818
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=dWLYIOSQw7" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=dWLYIOSQw7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/life13010219" target="_blank" >10.3390/life13010219</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Outcome of Continuous Positive Airway Pressure Adherence Based on Nasal Endoscopy and the Measurement of Nasal Patency-A Prospective Study
Popis výsledku v původním jazyce
The gold standard for treating obstructive sleep apnea in adults is continuous positive airway pressure (CPAP). However, it can be difficult to convince patients to adhere to this therapy. The aim of this study was to determine the relationship between nasal endoscopy findings/nose patency and CPAP adherence. Material and methods: A cohort of 450 consecutive patients suspected of having OSA were prospectively enrolled. For further analyses, 47 OSA patients undergoing CPAP treatment were selected (13 females and 34 males, average age, 65.3 years, BMI 34.1, apnea-hypopnea index. AHI 51.0). The patients were divided into two groups: patients with good CPAP adherence (n = 35) and patients who did not adhere to CPAP therapy (n = 12). The influence of nasal endoscopy and flow measurement on CPAP adherence was explored. Results: We found a statistical independence between adherence to CPAP and AHI (p = 0.124), T90 (p = 0.502), endoscopic findings (p = 0.588) and nasal patency measured by a flowmeter (p = 0.498). Conclusions: In our studied sample, endoscopic findings and nasal patency measured by a flowmeter were not predictors of CPAP non-adherence in the first year of the treatment. Our data show that while an endoscopic finding in the nasal cavity could indicate that a patient has a severe obstruction, compliance with CPAP therapy is not reduced in these patients and neither is it reduced with a decrease in nasal flow, according to our observation.
Název v anglickém jazyce
Outcome of Continuous Positive Airway Pressure Adherence Based on Nasal Endoscopy and the Measurement of Nasal Patency-A Prospective Study
Popis výsledku anglicky
The gold standard for treating obstructive sleep apnea in adults is continuous positive airway pressure (CPAP). However, it can be difficult to convince patients to adhere to this therapy. The aim of this study was to determine the relationship between nasal endoscopy findings/nose patency and CPAP adherence. Material and methods: A cohort of 450 consecutive patients suspected of having OSA were prospectively enrolled. For further analyses, 47 OSA patients undergoing CPAP treatment were selected (13 females and 34 males, average age, 65.3 years, BMI 34.1, apnea-hypopnea index. AHI 51.0). The patients were divided into two groups: patients with good CPAP adherence (n = 35) and patients who did not adhere to CPAP therapy (n = 12). The influence of nasal endoscopy and flow measurement on CPAP adherence was explored. Results: We found a statistical independence between adherence to CPAP and AHI (p = 0.124), T90 (p = 0.502), endoscopic findings (p = 0.588) and nasal patency measured by a flowmeter (p = 0.498). Conclusions: In our studied sample, endoscopic findings and nasal patency measured by a flowmeter were not predictors of CPAP non-adherence in the first year of the treatment. Our data show that while an endoscopic finding in the nasal cavity could indicate that a patient has a severe obstruction, compliance with CPAP therapy is not reduced in these patients and neither is it reduced with a decrease in nasal flow, according to our observation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Life
ISSN
0024-3019
e-ISSN
2075-1729
Svazek periodika
13
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
219
Kód UT WoS článku
000915203100001
EID výsledku v databázi Scopus
2-s2.0-85146522613