Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F23%3A10465560" target="_blank" >RIV/00669806:_____/23:10465560 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/23:10465560
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=FD1N.78ChE" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=FD1N.78ChE</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/PEC.0000000000003018" target="_blank" >10.1097/PEC.0000000000003018</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
Popis výsledku v původním jazyce
Objectives: Stroke volume (SV) and cardiac output monitoring is a comerstone of hemodynamic assessment. Noninvasive technologies are increasingly used in children. This study compared SV measurements obtained by transcutaneous Doppler ultrasound techniques (ultrasonic cardiac output monitor), transthoraic echocardiography jugular (TTE-J), and parasternal (TTE-P) views performed vy pediatric intensivists (OP-As) with limited training in cardiac sonography (20 previous examinations) and pediatric cardiologists (OP-Bs) with limited training in USCOM (30) previous examinations) in spontaneously ventilating children. Methods: A single-center study was conducted in 37 children. Each operator obtained 3sets of USCOM SV measurements within a period of 3 to 5 minutes, followed with TTE measurements from both apical and jugular views. The investigators were blinded to each other's results to prevent visual and auditory bias. Conclusions: Our findings show that the methods are not interchangeable because SV values by USCOM are higher in comparison with the SV values obtained by TTE. Both methods have low level of intraobserver variability. The SV measurements obtained by TTE-P were significantly lower compared with the TTE-J for the operator with limited training in echocardiography. The TTE-P requires longer practice compared with the TTE-J; therefore, we recommend to prefer TTE-J to TTE-P for inexperienced operators.
Název v anglickém jazyce
Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children: A Prospective Observational Cohort Study
Popis výsledku anglicky
Objectives: Stroke volume (SV) and cardiac output monitoring is a comerstone of hemodynamic assessment. Noninvasive technologies are increasingly used in children. This study compared SV measurements obtained by transcutaneous Doppler ultrasound techniques (ultrasonic cardiac output monitor), transthoraic echocardiography jugular (TTE-J), and parasternal (TTE-P) views performed vy pediatric intensivists (OP-As) with limited training in cardiac sonography (20 previous examinations) and pediatric cardiologists (OP-Bs) with limited training in USCOM (30) previous examinations) in spontaneously ventilating children. Methods: A single-center study was conducted in 37 children. Each operator obtained 3sets of USCOM SV measurements within a period of 3 to 5 minutes, followed with TTE measurements from both apical and jugular views. The investigators were blinded to each other's results to prevent visual and auditory bias. Conclusions: Our findings show that the methods are not interchangeable because SV values by USCOM are higher in comparison with the SV values obtained by TTE. Both methods have low level of intraobserver variability. The SV measurements obtained by TTE-P were significantly lower compared with the TTE-J for the operator with limited training in echocardiography. The TTE-P requires longer practice compared with the TTE-J; therefore, we recommend to prefer TTE-J to TTE-P for inexperienced operators.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30209 - Paediatrics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Pediatric Emergency Care
ISSN
0749-5161
e-ISSN
1535-1815
Svazek periodika
39
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
680-684
Kód UT WoS článku
001057981800009
EID výsledku v databázi Scopus
2-s2.0-85169180202