Newborn Hearing Screening - An Implementation Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F24%3A10481582" target="_blank" >RIV/00669806:_____/24:10481582 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/24:00136793 RIV/00216208:11140/24:10481582
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=RRr1epATaE" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=RRr1epATaE</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21873/invivo.13650" target="_blank" >10.21873/invivo.13650</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Newborn Hearing Screening - An Implementation Analysis
Popis výsledku v původním jazyce
BACKGROUND/AIM: Hearing impairment affects a small but significant percentage of newborns (0.1-0.4%). Newborn hearing screening (NHS) is recommended for early detection and treatment. The implementation of NHS can vary among countries. In this study, we present the methodology, organization, and technical requirements of NHS. This study analyzed results from a tertiary hospital, identified issues, and proposed solutions. PATIENTS AND METHODS: In the studied region, there are five maternity hospitals and a perinatal intensive care center and in 2020, there were 5,864 live births. Screening is performed at three levels. The first screening is conducted on the 2(nd)-3(rd) day of a newborn's life in a maternity hospital, the first rescreening on the 3(rd)-6(th) week at a relevant ENT department, and the second rescreening on the 3(rd)-6(th) month of life at the regional screening center where the central database is also held. RESULTS: In the studied region, 5,793 out of 5,864 (98.79%) newborns received NHS in 2020. Of these, 120 (2.07%) were tested positive on their first screening. Ninety-four patients (78.3%) of those attended the ENT department for a first rescreening. Thirty-four patients (0.59% of total) were tested positive again and referred to the regional screening center. Out of the 27 patients who attended the second rescreening, four (0.07% of the total) were ultimately diagnosed with hearing impairment. CONCLUSION: Our study found that newborn hearing screening (NHS) in our region achieved a high compliance rate of 98.8% for initial screenings in 2020. However, challenges remain in the rescreening process due to data management issues, inter-regional cooperation, and public awareness. The recent implementation of mandatory screenings, updated guidelines, and a centralized database is expected to enhance the effectiveness of NHS. Further research is needed to evaluate these improvements.
Název v anglickém jazyce
Newborn Hearing Screening - An Implementation Analysis
Popis výsledku anglicky
BACKGROUND/AIM: Hearing impairment affects a small but significant percentage of newborns (0.1-0.4%). Newborn hearing screening (NHS) is recommended for early detection and treatment. The implementation of NHS can vary among countries. In this study, we present the methodology, organization, and technical requirements of NHS. This study analyzed results from a tertiary hospital, identified issues, and proposed solutions. PATIENTS AND METHODS: In the studied region, there are five maternity hospitals and a perinatal intensive care center and in 2020, there were 5,864 live births. Screening is performed at three levels. The first screening is conducted on the 2(nd)-3(rd) day of a newborn's life in a maternity hospital, the first rescreening on the 3(rd)-6(th) week at a relevant ENT department, and the second rescreening on the 3(rd)-6(th) month of life at the regional screening center where the central database is also held. RESULTS: In the studied region, 5,793 out of 5,864 (98.79%) newborns received NHS in 2020. Of these, 120 (2.07%) were tested positive on their first screening. Ninety-four patients (78.3%) of those attended the ENT department for a first rescreening. Thirty-four patients (0.59% of total) were tested positive again and referred to the regional screening center. Out of the 27 patients who attended the second rescreening, four (0.07% of the total) were ultimately diagnosed with hearing impairment. CONCLUSION: Our study found that newborn hearing screening (NHS) in our region achieved a high compliance rate of 98.8% for initial screenings in 2020. However, challenges remain in the rescreening process due to data management issues, inter-regional cooperation, and public awareness. The recent implementation of mandatory screenings, updated guidelines, and a centralized database is expected to enhance the effectiveness of NHS. Further research is needed to evaluate these improvements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
In Vivo
ISSN
0258-851X
e-ISSN
1791-7549
Svazek periodika
38
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GR - Řecká republika
Počet stran výsledku
8
Strana od-do
1939-1946
Kód UT WoS článku
001266321000049
EID výsledku v databázi Scopus
2-s2.0-85197202783