Three-dimensional personalized porous polyethylen cranioplasty in patients at increased risk of surgical site infection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F24%3A10485378" target="_blank" >RIV/00669806:_____/24:10485378 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/24:A2503AKC RIV/00216208:11140/24:10485378 RIV/00843989:_____/24:E0111537
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=GRi_GBH5HE" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=GRi_GBH5HE</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00701-024-06281-x" target="_blank" >10.1007/s00701-024-06281-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Three-dimensional personalized porous polyethylen cranioplasty in patients at increased risk of surgical site infection
Popis výsledku v původním jazyce
BackgroundSurgical site infection (SSI) is the most consistently reported complication of cranioplasty. No material showed a categorical superiority in the incidence of infection. Porous polyethylene (PE) is considered a low risk material regarding SSI. However, the literature data are very limited. Thus, our objective was to verify the assumed low incidence of SSI after PE cranioplasty in patients at high risk of SSI. The primary objective was the infection rate, while secondary objectives were implant exposure, revision and cosmetic results.MethodPatients who underwent three-dimensional (3D) personalized PE cranioplasty in the period 2014-2023 were evaluated prospectively. Only patients with an increased risk of SSI, and a satisfactory clinical conditions were included in the study.ResultsThirty procedures were performed in 30 patients. Cranioplasty was performed 23 times after hemispheric decompressive craniectomy, five times after limited size craniotomy and two times after bifrontal decompressive craniectomy. Risk factors for the development of infection were 18 previous SSIs, 16 previous repeated revision surgeries, four intraoperatively opened frontal sinuses and two times radiotherapy. Neither infection nor implant exposure was detected in any patient. All patients were satisfied with the aesthetic result. In two cases, a revision was performed due to postoperative epidural hematoma.ConclusionsThree-dimensional personalized PE cranioplasty is associated with an extremely low incidence of SSI even in high-risk patients. However, our conclusions can only be confirmed in larger studies.
Název v anglickém jazyce
Three-dimensional personalized porous polyethylen cranioplasty in patients at increased risk of surgical site infection
Popis výsledku anglicky
BackgroundSurgical site infection (SSI) is the most consistently reported complication of cranioplasty. No material showed a categorical superiority in the incidence of infection. Porous polyethylene (PE) is considered a low risk material regarding SSI. However, the literature data are very limited. Thus, our objective was to verify the assumed low incidence of SSI after PE cranioplasty in patients at high risk of SSI. The primary objective was the infection rate, while secondary objectives were implant exposure, revision and cosmetic results.MethodPatients who underwent three-dimensional (3D) personalized PE cranioplasty in the period 2014-2023 were evaluated prospectively. Only patients with an increased risk of SSI, and a satisfactory clinical conditions were included in the study.ResultsThirty procedures were performed in 30 patients. Cranioplasty was performed 23 times after hemispheric decompressive craniectomy, five times after limited size craniotomy and two times after bifrontal decompressive craniectomy. Risk factors for the development of infection were 18 previous SSIs, 16 previous repeated revision surgeries, four intraoperatively opened frontal sinuses and two times radiotherapy. Neither infection nor implant exposure was detected in any patient. All patients were satisfied with the aesthetic result. In two cases, a revision was performed due to postoperative epidural hematoma.ConclusionsThree-dimensional personalized PE cranioplasty is associated with an extremely low incidence of SSI even in high-risk patients. However, our conclusions can only be confirmed in larger studies.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Neurochirurgica
ISSN
0001-6268
e-ISSN
0942-0940
Svazek periodika
166
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
8
Strana od-do
383
Kód UT WoS článku
001321759300001
EID výsledku v databázi Scopus
2-s2.0-85205073387