False-positive cardiac troponin elevations in skeletal muscle disease: Clinical relevance, mechanisms, and laboratory approaches
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F25%3A10504806" target="_blank" >RIV/00669806:_____/25:10504806 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/25:10504806
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=mFAgRTt63Q" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=mFAgRTt63Q</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.935683" target="_blank" >10.33549/physiolres.935683</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
False-positive cardiac troponin elevations in skeletal muscle disease: Clinical relevance, mechanisms, and laboratory approaches
Popis výsledku v původním jazyce
Cardiac troponins are indispensable biomarkers for the diagnosis of acute myocardial infarction, but false-positive elevations that contradict the clinical picture remain a significant challenge in laboratory medicine. Analytical interferences may arise from macrotroponins, heterophile or anti-troponin antibodies, and the limited cardiac specificity of high-sensitivity troponin T (hs-cTnT) in skeletal muscle disease. Recent studies show that hs-cTnT is elevated in up to two-thirds of patients with myopathies, while high-sensitivity troponin I (hs-cTnI) is largely unaffected, underscoring the diagnostic advantage of hs-cTnI in this setting. A pragmatic diagnostic approach should combine clinical plausibility with stepwise laboratory testing. First, preanalytical factors such as sample mislabeling, fibrin clots, or hemolysis must be excluded and the measurement repeated. If the results remain incongruent, an alternative assay - ideally hs-cTnI - should be performed. Further evaluation may include heterophile-blocking reagents, polyethylene glycol precipitation to screen for macro-analytes, and, where available, confirmatory techniques such as gel filtration chromatography or immunoglobulin depletion (protein A/G). Although these strategies can help identify assay interference, there is no universally accepted gold standard. Awareness of false-positive elevations, careful interpretation of discordant troponin results, and effective collaboration between laboratories and clinicians are essential to prevent misdiagnosis and unnecessary interventions. Clear documentation of confirmed interferences further ensures safe patient management and provides guidance on which assays are reliable for future tests.
Název v anglickém jazyce
False-positive cardiac troponin elevations in skeletal muscle disease: Clinical relevance, mechanisms, and laboratory approaches
Popis výsledku anglicky
Cardiac troponins are indispensable biomarkers for the diagnosis of acute myocardial infarction, but false-positive elevations that contradict the clinical picture remain a significant challenge in laboratory medicine. Analytical interferences may arise from macrotroponins, heterophile or anti-troponin antibodies, and the limited cardiac specificity of high-sensitivity troponin T (hs-cTnT) in skeletal muscle disease. Recent studies show that hs-cTnT is elevated in up to two-thirds of patients with myopathies, while high-sensitivity troponin I (hs-cTnI) is largely unaffected, underscoring the diagnostic advantage of hs-cTnI in this setting. A pragmatic diagnostic approach should combine clinical plausibility with stepwise laboratory testing. First, preanalytical factors such as sample mislabeling, fibrin clots, or hemolysis must be excluded and the measurement repeated. If the results remain incongruent, an alternative assay - ideally hs-cTnI - should be performed. Further evaluation may include heterophile-blocking reagents, polyethylene glycol precipitation to screen for macro-analytes, and, where available, confirmatory techniques such as gel filtration chromatography or immunoglobulin depletion (protein A/G). Although these strategies can help identify assay interference, there is no universally accepted gold standard. Awareness of false-positive elevations, careful interpretation of discordant troponin results, and effective collaboration between laboratories and clinicians are essential to prevent misdiagnosis and unnecessary interventions. Clear documentation of confirmed interferences further ensures safe patient management and provides guidance on which assays are reliable for future tests.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30100 - Basic medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Svazek periodika
74
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
885-889
Kód UT WoS článku
001631813000016
EID výsledku v databázi Scopus
2-s2.0-105020866848