Continuous elimination methods in burn patients from the point of view of a nurse
Popis výsledku v původním jazyce
Continuous elimination methods are part of complex therapeutic methods used in critically ill patients after burn injuries.We have been using CVVH (continual veno?venous hemofiltration) in our center since 1995. We use CVVH in patients after burn injurywho present with systemic inflammatory syndrome, multiorgan dysfunction or multiorgan failure. From 1995 till 2001, elimination was performed under the supervision of an intensive care unit nephrologist. In recent years we have provided CVVH to burn patients independently. A nurse places sets in the device, flushes the sets with saline with heparine and subsequently drains this off into a collecting bag. After the device is tested it is ready to be used on a patient. The nurse calls a MD and under his supervision begins the elimination. Elimination parameters are set by the attending MD, and the nurse has a full written record of this throughout the elimination. The MD is informed of any complications during the elimination. If an alarm
Název v anglickém jazyce
Continuous elimination methods in burn patients from the point of view of a nurse
Popis výsledku anglicky
Continuous elimination methods are part of complex therapeutic methods used in critically ill patients after burn injuries.We have been using CVVH (continual veno?venous hemofiltration) in our center since 1995. We use CVVH in patients after burn injurywho present with systemic inflammatory syndrome, multiorgan dysfunction or multiorgan failure. From 1995 till 2001, elimination was performed under the supervision of an intensive care unit nephrologist. In recent years we have provided CVVH to burn patients independently. A nurse places sets in the device, flushes the sets with saline with heparine and subsequently drains this off into a collecting bag. After the device is tested it is ready to be used on a patient. The nurse calls a MD and under his supervision begins the elimination. Elimination parameters are set by the attending MD, and the nurse has a full written record of this throughout the elimination. The MD is informed of any complications during the elimination. If an alarm
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FJ - Chirurgie včetně transplantologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta chirurgiae plasticae
ISSN
0001-5423
e-ISSN
—
Svazek periodika
47
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—