Posouzení využití Beta-trace proteinu (BTP) měřeného v séru pro odhad stupně glomerulární filtrace. Srovnání s cystatinem C měřeným v séru.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F06%3A00014056" target="_blank" >RIV/00843989:_____/06:00014056 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of serum ß-trace protein (BTP) measurement in the prediction of glomerular filtration rate. Comparison with serum cystatin C
Popis výsledku v původním jazyce
Serum BTP measurement is sometimes believed to be an alternative marker of glomerular filtration rate (GFR) assessment. The aim of the present work was to investigate the correlation between creatinine, cystatin C, and BTP values in sera and to compare the diagnostic efficacy for serum BTP and cystatin C with the glomerular filtration rate estimate. 25 individuals were tested. GFR was estimated from creatinine clearance, serum cystatin C and BTP and urine ?-1 microglobulin, albumin, GMT and creatinine were measured. BTP values correlated with cystatin C (r = 0.75;p < 0.01), creatinine (r = 0.73, p < 0.01), GFR (r = ?0.46; p = 0.02), urine ?-1-microglobulin (r = 0.66; p < 0.01). The diagnostic efficacy of BTP for reduced GFR was insufficient and the calculation of GFR with BTP was not included in the regression model.
Název v anglickém jazyce
Assessment of serum ß-trace protein (BTP) measurement in the prediction of glomerular filtration rate. Comparison with serum cystatin C
Popis výsledku anglicky
Serum BTP measurement is sometimes believed to be an alternative marker of glomerular filtration rate (GFR) assessment. The aim of the present work was to investigate the correlation between creatinine, cystatin C, and BTP values in sera and to compare the diagnostic efficacy for serum BTP and cystatin C with the glomerular filtration rate estimate. 25 individuals were tested. GFR was estimated from creatinine clearance, serum cystatin C and BTP and urine ?-1 microglobulin, albumin, GMT and creatinine were measured. BTP values correlated with cystatin C (r = 0.75;p < 0.01), creatinine (r = 0.73, p < 0.01), GFR (r = ?0.46; p = 0.02), urine ?-1-microglobulin (r = 0.66; p < 0.01). The diagnostic efficacy of BTP for reduced GFR was insufficient and the calculation of GFR with BTP was not included in the regression model.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
150
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
2
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—