External and internal fixators for treatment of complicated fractures in traumatology and orthopaedics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F14%3AE0104476" target="_blank" >RIV/00843989:_____/14:E0104476 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
External and internal fixators for treatment of complicated fractures in traumatology and orthopaedics
Popis výsledku v původním jazyce
In this paper, doctors want to draw attention to the possibilities of treatment of complicated fractures of limbs and pelvis. They present their own experiences with the treatment of these fractures by using various types of internal and external fixation. In this paper, engineers report about the new design, testing and numerical modelling of external and internal fixators inv ented at the VŠB - Technical University of Ostrava and at the Trauma Centre of The University Hospital in Ostrava and at the Pardubice Regional Hospital together with MEDIN a.s. company. These fixators are intended for the treatment of open, unstable, extraarticular or intraarticular and other types of complicated fractures in traumatology and orthopaedics for humans or animalslimbs. The new design of external fixators is based on the development of Ilizarov and other techniques (i.e. shape and weight optimization based on composite materials, application of smart materials, nanotechnology, low x-ray absorption
Název v anglickém jazyce
External and internal fixators for treatment of complicated fractures in traumatology and orthopaedics
Popis výsledku anglicky
In this paper, doctors want to draw attention to the possibilities of treatment of complicated fractures of limbs and pelvis. They present their own experiences with the treatment of these fractures by using various types of internal and external fixation. In this paper, engineers report about the new design, testing and numerical modelling of external and internal fixators inv ented at the VŠB - Technical University of Ostrava and at the Trauma Centre of The University Hospital in Ostrava and at the Pardubice Regional Hospital together with MEDIN a.s. company. These fixators are intended for the treatment of open, unstable, extraarticular or intraarticular and other types of complicated fractures in traumatology and orthopaedics for humans or animalslimbs. The new design of external fixators is based on the development of Ilizarov and other techniques (i.e. shape and weight optimization based on composite materials, application of smart materials, nanotechnology, low x-ray absorption
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2014. 20th International Conference, May 12-15, 2014, Svratka, Czech Republic
ISBN
978-80-214-4871-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
180-183
Název nakladatele
University of Technology
Místo vydání
Brno
Místo konání akce
Svratka, Czech Republic
Datum konání akce
12. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000364573900038