Results of Cutler-Beard procedure for reconstruction of extensive full thickness upper eyelid defects following tumor resection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F16%3AE0105423" target="_blank" >RIV/00843989:_____/16:E0105423 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/16:10360668
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00347-015-0146-z" target="_blank" >http://dx.doi.org/10.1007/s00347-015-0146-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00347-015-0146-z" target="_blank" >10.1007/s00347-015-0146-z</a>
Alternativní jazyky
Jazyk výsledku
němčina
Název v původním jazyce
Ergebnisse nach Cutler-Beard-Plastik zur Rekonstruktion ausgedehnter Oberliddefekte nach Tumorexzision
Popis výsledku v původním jazyce
Hintergrund: In der Rekonstruktion großer durchgreifender Oberliddefekte hat sich die Brückenlappenplastik nach Cutler-Beard etabliert. Ziel dieser Studie ist es, unsere Erfahrungen mit Technik, Komplikationen und Ergebnissen dieser Kutaneomuskulokonjunktivallappenplastik nach Tumorexzision darzustellen. Patienten und Methoden: Bei 18 Patienten wurde ein großer durchgreifender Oberliddefekt nach Tumorresektion mittels Cutler-Beard-Brückenlappenplastik des Unterlides versorgt. Vier Patienten erhielten zusätzlich Spendersklera, 1 Patient kontralateralen Tarsus als Lidstabilisator. Ergebnisse: Chirurgisch erfolgreich konnte der Eingriff bei allen Patienten durchgeführt werden ohne Verletzung der Unterlidbrücke oder Infektion. Bei 3 der 13 Plastiken ohne zusätzlichen Lidstabilisator (23?%) kam es zu einem Oberlidentropium, das einen Revisionseingriff mit sekundärer Skleraimplantation erforderte. Die 5 primär mit Sklera- oder Tarsustransplantaten rekonstruierten Oberlider entwickelten keine Entropiumstellung. Schlussfolgerungen: Die Cutler-Beard-Brückenlappenplastik, die im Falle besonders ausgedehnter Defekte (>?75?% der Lidlänge) mit der Transplantation von Stabilisationsersatzgewebe kombiniert werden kann, ist eine verlässliche Methode zur Rekonstruktion großer durchgreifender Oberliddefekte nach Tumorexzision.
Název v anglickém jazyce
Results of Cutler-Beard procedure for reconstruction of extensive full thickness upper eyelid defects following tumor resection
Popis výsledku anglicky
Background: The Cutler-Beard bridge flap technique is an established method for reconstruction of large full thickness upper eyelid defects. The purpose of the present study was to report experiences with the surgical technique, complications and results of this cutaneoconjunctival flap procedure following tumor resection. Patients and methods: A total of 18 patients with extensive full thickness upper eyelid defects after tumor excision underwent a Cutler-Beard procedure. Of the patients four received an additional eye bank scleral implant and one received an additional free tarsal graft from the fellow upper eyelid to enhance eyelid stability. Results: The Cutler-Beard bridge flap technique was surgically feasible in all patients without causing damage to the lower eyelid bridge or resulting in any infections. Out of the 13 reconstructions without additional stabilizing tissue 3 (23?%) developed an upper eyelid entropion that was successfully managed using a secondary scleral implant. None of the five reconstructions using additional scleral or tarsal tissue showed an entropion of the upper eyelid. Conclusion: The Cutler-Beard bridge flap technique, which can be combined with grafting additional stabilization tissue in defects exceeding 75?% of the upper eyelid length, is a reliable method for reconstruction of large full thickness upper eyelid defects following tumor excision.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ophthalmologe
ISSN
0941-293X
e-ISSN
—
Svazek periodika
Jg. 113
Číslo periodika v rámci svazku
Nr. 4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
309-313
Kód UT WoS článku
000374375900009
EID výsledku v databázi Scopus
—