Is jugular bulb oximetry monitoring associated with outcome in out of hospital cardiac arrest patients?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F21%3AE0109078" target="_blank" >RIV/00843989:_____/21:E0109078 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/content/pdf/10.1007/s10877-020-00530-x.pdf" target="_blank" >https://link.springer.com/content/pdf/10.1007/s10877-020-00530-x.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10877-020-00530-x" target="_blank" >10.1007/s10877-020-00530-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Is jugular bulb oximetry monitoring associated with outcome in out of hospital cardiac arrest patients?
Popis výsledku v původním jazyce
Cerebral protection against secondary hypoxic-ischemic brain injury is a key priority area in post-resuscitation intensive care management in survivors of cardiac arrest. Nevertheless, the current understanding of the incidence, diagnosis and its' impact on neurological outcome remains undetermined. The aim of this study was to evaluate jugular bulb oximetry as a potential monitoring modality to detect the incidences of desaturation episodes during post-cardiac arrest intensive care management and to evaluate their subsequent impact on neurological outcome. We conducted a prospective, observational study in unconscious adult patients admitted to the intensive care unit who had successful resuscitation following out of hospital cardiac arrest of presumed cardiac causes. All the patients were treated as per European Resuscitation Council 2015 guidelines and they received jugular bulb catheter. Jugular bulb oximetry measurements were performed at six hourly intervals. The neurological outcomes were evaluated on 90th day after the cardiac arrest by cerebral performance categories scale. Forty patients met the eligibility criteria. Measurements of jugular venous oxygen saturation were performed for 438 times. Altogether, we found 2 incidences of jugular bulb oxygen saturation less than 50% (2/438; 0.46%), and 4 incidences when it was less than 55% (4/438; 0.91%). The study detected an association between SjVO2 and CO2 (r = 0.26), each 1 kPa increase in CO2 led to an increase in SjvO2 by 3.4% + / - 0.67 (p < 0.0001). There was no association between SjvO2 and PaO2 or SjvO2 and MAP. We observed a statistically significant higher mean SjvO2 (8.82% + / - 2.05, p < 0.0001) in unfavorable outcome group. The episodes of brain hypoxia detected by jugular bulb oxygen saturation were rare during post-resuscitation intensive care management in out of hospital cardiac arrest patients. Therefore, this modality of monitoring may not yield any additional information towards preventi...
Název v anglickém jazyce
Is jugular bulb oximetry monitoring associated with outcome in out of hospital cardiac arrest patients?
Popis výsledku anglicky
Cerebral protection against secondary hypoxic-ischemic brain injury is a key priority area in post-resuscitation intensive care management in survivors of cardiac arrest. Nevertheless, the current understanding of the incidence, diagnosis and its' impact on neurological outcome remains undetermined. The aim of this study was to evaluate jugular bulb oximetry as a potential monitoring modality to detect the incidences of desaturation episodes during post-cardiac arrest intensive care management and to evaluate their subsequent impact on neurological outcome. We conducted a prospective, observational study in unconscious adult patients admitted to the intensive care unit who had successful resuscitation following out of hospital cardiac arrest of presumed cardiac causes. All the patients were treated as per European Resuscitation Council 2015 guidelines and they received jugular bulb catheter. Jugular bulb oximetry measurements were performed at six hourly intervals. The neurological outcomes were evaluated on 90th day after the cardiac arrest by cerebral performance categories scale. Forty patients met the eligibility criteria. Measurements of jugular venous oxygen saturation were performed for 438 times. Altogether, we found 2 incidences of jugular bulb oxygen saturation less than 50% (2/438; 0.46%), and 4 incidences when it was less than 55% (4/438; 0.91%). The study detected an association between SjVO2 and CO2 (r = 0.26), each 1 kPa increase in CO2 led to an increase in SjvO2 by 3.4% + / - 0.67 (p < 0.0001). There was no association between SjvO2 and PaO2 or SjvO2 and MAP. We observed a statistically significant higher mean SjvO2 (8.82% + / - 2.05, p < 0.0001) in unfavorable outcome group. The episodes of brain hypoxia detected by jugular bulb oxygen saturation were rare during post-resuscitation intensive care management in out of hospital cardiac arrest patients. Therefore, this modality of monitoring may not yield any additional information towards preventi...
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30223 - Anaesthesiology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of clinical monitoring and computing
ISSN
1387-1307
e-ISSN
1573-2614
Svazek periodika
35
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
741-748
Kód UT WoS článku
000534430100002
EID výsledku v databázi Scopus
2-s2.0-85085319007