Simultaneous presbyopia and astigmatism correction with a novel trifocal toric intraocular lens - a one-year follow-up
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F22%3AE0109647" target="_blank" >RIV/00843989:_____/22:E0109647 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/22:43923741 RIV/00216208:11110/22:10445543 RIV/00216208:11120/22:43923741 RIV/00216208:11150/22:10445543
Výsledek na webu
<a href="https://www.mdpi.com/2077-0383/11/14/4194" target="_blank" >https://www.mdpi.com/2077-0383/11/14/4194</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jcm11144194" target="_blank" >10.3390/jcm11144194</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous presbyopia and astigmatism correction with a novel trifocal toric intraocular lens - a one-year follow-up
Popis výsledku v původním jazyce
The current investigation evaluates the efficiency of the trifocal toric Liberty 677MTY intraocular lens (IOL) in correcting preoperative corneal astigmatism in cataract patients demanding spectacle independence. The retrospective evaluation included 28 eyes of 15 patients with preoperative corneal astigmatism of at least 1.0 Dioptre (D). All patients were followed up for one year postoperatively. Residual refractive errors and visual acuities at multiple distances were measured. Binocular visual acuity and contrast sensitivity defocus curves were plotted. Visual functions and patient satisfaction were assessed. The efficiency of astigmatism correction was determined using the vector analysis method. The mean spherical equivalent refraction (SEQ) improved from 2.72 ± 1.62 D to 0.10 ± 0.48 D. The cylindric refraction decreased from 1.18 ± 0.45 D to 0.16 ± 0.31 D. Vector analysis proved efficient astigmatism correction with a centroid of 0.10 ± 0.34 D at 161°. Ninety-two percent of eyes resulted within 0.5 D from the target refraction. Visual acuities were 0.1 logMAR or better from +1.0 to -3.5 D defocus values. Visual tasks could be performed without major difficulties. Our patients were highly satisfied. Refractive and visual outcomes with the investigated presbyopia-correcting toric IOL are predictable and the lens provides excellent trifocal vision.
Název v anglickém jazyce
Simultaneous presbyopia and astigmatism correction with a novel trifocal toric intraocular lens - a one-year follow-up
Popis výsledku anglicky
The current investigation evaluates the efficiency of the trifocal toric Liberty 677MTY intraocular lens (IOL) in correcting preoperative corneal astigmatism in cataract patients demanding spectacle independence. The retrospective evaluation included 28 eyes of 15 patients with preoperative corneal astigmatism of at least 1.0 Dioptre (D). All patients were followed up for one year postoperatively. Residual refractive errors and visual acuities at multiple distances were measured. Binocular visual acuity and contrast sensitivity defocus curves were plotted. Visual functions and patient satisfaction were assessed. The efficiency of astigmatism correction was determined using the vector analysis method. The mean spherical equivalent refraction (SEQ) improved from 2.72 ± 1.62 D to 0.10 ± 0.48 D. The cylindric refraction decreased from 1.18 ± 0.45 D to 0.16 ± 0.31 D. Vector analysis proved efficient astigmatism correction with a centroid of 0.10 ± 0.34 D at 161°. Ninety-two percent of eyes resulted within 0.5 D from the target refraction. Visual acuities were 0.1 logMAR or better from +1.0 to -3.5 D defocus values. Visual tasks could be performed without major difficulties. Our patients were highly satisfied. Refractive and visual outcomes with the investigated presbyopia-correcting toric IOL are predictable and the lens provides excellent trifocal vision.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of clinical medicine
ISSN
2077-0383
e-ISSN
2077-0383
Svazek periodika
11
Číslo periodika v rámci svazku
14
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
12
Strana od-do
1-12
Kód UT WoS článku
000832143200001
EID výsledku v databázi Scopus
2-s2.0-85136434109