Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F22%3AE0109946" target="_blank" >RIV/00843989:_____/22:E0109946 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/22:A2302IW2 RIV/61989100:27240/22:10250070
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s00068-022-02020-y" target="_blank" >https://link.springer.com/article/10.1007/s00068-022-02020-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00068-022-02020-y" target="_blank" >10.1007/s00068-022-02020-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
Popis výsledku v původním jazyce
Purpose: Treatment of pelvic fractures is often complicated. Here, we intended to evaluate the intraoperative benefits of using 2D computer navigation when compared with traditional fluoroscopy on X-ray burden, surgical time and screw placement accuracy. Methods: In this study, we retrospectively evaluated the records of 25 patients who underwent osteosynthesis of a posterior pelvic fracture using fluoroscopy at the University Hospital Ostrava, Czech Republic between 2011 and 2019, and 32 patients from the same department and period in whom 2D computer navigation was used. Results: Intraoperative X-ray burden was significantly lower in the group with 2D computer navigation (median 650 vs 1024 cGy/cm2), as was the duration of the surgery (41 vs 45 min). This was most obvious where two screws were inserted (X-ray dose of 994 vs 1847 cGy/cm2 and 48 vs 70 min, respectively). Correction of the path for wire placement after the original drilling was necessary in 2 patients (6%) from the 2D computer navigation group and 15 patients from the fluoroscopy group (60%). Still, no malposition of the screws nor dislocation of the posterior pelvic segment after 12 months was observed in any patient of either group; of complications, only three superficial infections in the 2D navigation group and 2 in the fluoroscopy group were observed. Conclusion: 2D computer navigation is a safe and accurate method for placement of screws during posterior pelvic fracture osteosynthesis, associated with lower intraoperative radiation burden and shorter surgical times compared to standard fluoroscopy, especially if two screws are inserted.
Název v anglickém jazyce
Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
Popis výsledku anglicky
Purpose: Treatment of pelvic fractures is often complicated. Here, we intended to evaluate the intraoperative benefits of using 2D computer navigation when compared with traditional fluoroscopy on X-ray burden, surgical time and screw placement accuracy. Methods: In this study, we retrospectively evaluated the records of 25 patients who underwent osteosynthesis of a posterior pelvic fracture using fluoroscopy at the University Hospital Ostrava, Czech Republic between 2011 and 2019, and 32 patients from the same department and period in whom 2D computer navigation was used. Results: Intraoperative X-ray burden was significantly lower in the group with 2D computer navigation (median 650 vs 1024 cGy/cm2), as was the duration of the surgery (41 vs 45 min). This was most obvious where two screws were inserted (X-ray dose of 994 vs 1847 cGy/cm2 and 48 vs 70 min, respectively). Correction of the path for wire placement after the original drilling was necessary in 2 patients (6%) from the 2D computer navigation group and 15 patients from the fluoroscopy group (60%). Still, no malposition of the screws nor dislocation of the posterior pelvic segment after 12 months was observed in any patient of either group; of complications, only three superficial infections in the 2D navigation group and 2 in the fluoroscopy group were observed. Conclusion: 2D computer navigation is a safe and accurate method for placement of screws during posterior pelvic fracture osteosynthesis, associated with lower intraoperative radiation burden and shorter surgical times compared to standard fluoroscopy, especially if two screws are inserted.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30502 - Other medical science
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_049%2F0008441" target="_blank" >EF17_049/0008441: Inovativní léčebné metody pohybového aparátu v úrazové chirurgii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European journal of trauma and emergency surgery
ISSN
1863-9933
e-ISSN
1863-9941
Svazek periodika
48
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
4897-4902
Kód UT WoS článku
000821714700002
EID výsledku v databázi Scopus
2-s2.0-85133581397