Stereotactic radiotherapy in the management of ventricular tachycardias: more questions than answers?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F22%3AE0109954" target="_blank" >RIV/00843989:_____/22:E0109954 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/22:A2402KEI
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1877918222000594?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1877918222000594?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ccep.2022.06.010" target="_blank" >10.1016/j.ccep.2022.06.010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stereotactic radiotherapy in the management of ventricular tachycardias: more questions than answers?
Popis výsledku v původním jazyce
Stereotactic body radiotherapy is a recent promising therapeutic alternative in cases of failed catheter ablation for recurrent ventricular tachycardias (VTs) in patients with structural heart disease. Initial clinical experience with a single radiation dose of 25 Gy shows reasonable efficacy in the reduction of VT recurrences with acceptable acute toxicity. Many unanswered questions remain, including unknown mechanism of action, variable time to effect, optimal method of substrate targeting, long-term safety, and definition of an optimal candidate for this treatment.
Název v anglickém jazyce
Stereotactic radiotherapy in the management of ventricular tachycardias: more questions than answers?
Popis výsledku anglicky
Stereotactic body radiotherapy is a recent promising therapeutic alternative in cases of failed catheter ablation for recurrent ventricular tachycardias (VTs) in patients with structural heart disease. Initial clinical experience with a single radiation dose of 25 Gy shows reasonable efficacy in the reduction of VT recurrences with acceptable acute toxicity. Many unanswered questions remain, including unknown mechanism of action, variable time to effect, optimal method of substrate targeting, long-term safety, and definition of an optimal candidate for this treatment.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
<a href="/cs/project/NU20-02-00244" target="_blank" >NU20-02-00244: Stereotaktická ablativní radiochirurgie rekurentní komorové tachykardie u strukturního onemocnění srdce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cardiac electrophysiology clinics
ISSN
1877-9182
e-ISSN
1877-9190
Svazek periodika
14
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
779-792
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85141970539