Echogenicity of brain structures in Huntington ´s disease patients evaluated by transcranial sonography - magnetic resonance fusion imaging using virtual navigator and digital image analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F23%3AE0110574" target="_blank" >RIV/00843989:_____/23:E0110574 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/23:00079130 RIV/00216224:14110/23:00131198 RIV/61988987:17110/23:A2402L3N RIV/00216208:11110/23:10466013
Výsledek na webu
<a href="https://www.thieme-connect.de/products/ejournals/abstract/10.1055/a-2081-1635" target="_blank" >https://www.thieme-connect.de/products/ejournals/abstract/10.1055/a-2081-1635</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1055/a-2081-1635" target="_blank" >10.1055/a-2081-1635</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Echogenicity of brain structures in Huntington ´s disease patients evaluated by transcranial sonography - magnetic resonance fusion imaging using virtual navigator and digital image analysis
Popis výsledku v původním jazyce
Purpose: Transcranial sonography (TCS) magnetic resonance (MR) fusion imaging and digital image analysis are useful tools for the evaluation of various brain pathologies. This study aimed to compare the echogenicity of predefined brain structures in Huntington's disease (HD) patients and healthy controls by TCS-MR fusion imaging using Virtual Navigator and digitized image analysis. Materials and methods: The echogenicity of the caudate nucleus (CN), substantia nigra (SN), lentiform nucleus (LN), insula, and brainstem raphe (BR) evaluated by TCS-MR fusion imaging using digitized image analysis was compared between 21 HD patients and 23 healthy controls. The cutoff values of echogenicity indices for the CN, LN, insula, and BR with optimal sensitivity and specificity were calculated using receiver operating characteristic analysis. Results: The mean echogenicity indices for the CN (67.0±22.6 vs. 37.9±7.6, p<0.0001), LN (110.7±23.6 vs. 59.7±11.1, p<0.0001), and insula (121.7±39.1 vs. 70.8±23.0, p<0.0001) were significantly higher in HD patients than in healthy controls. In contrast, BR echogenicity (24.8±5.3 vs. 30.1±5.3, p<0.001) was lower in HD patients than in healthy controls. The area under the curve was 90.9%, 95.5%, 84.1%, and 81.8% for the CN, LN, insula, and BR, respectively. The sensitivity and specificity were 86% and 96%, respectively, for the CN and 90% and 100%, respectively, for the LN. Conclusion: Increased CN, LN, and insula echogenicity and decreased BR echogenicity are typical findings in HD patients. The high sensitivity and specificity of the CN and LN hyperechogenicity in TCS-MR fusion imaging make them promising diagnostic markers for HD.
Název v anglickém jazyce
Echogenicity of brain structures in Huntington ´s disease patients evaluated by transcranial sonography - magnetic resonance fusion imaging using virtual navigator and digital image analysis
Popis výsledku anglicky
Purpose: Transcranial sonography (TCS) magnetic resonance (MR) fusion imaging and digital image analysis are useful tools for the evaluation of various brain pathologies. This study aimed to compare the echogenicity of predefined brain structures in Huntington's disease (HD) patients and healthy controls by TCS-MR fusion imaging using Virtual Navigator and digitized image analysis. Materials and methods: The echogenicity of the caudate nucleus (CN), substantia nigra (SN), lentiform nucleus (LN), insula, and brainstem raphe (BR) evaluated by TCS-MR fusion imaging using digitized image analysis was compared between 21 HD patients and 23 healthy controls. The cutoff values of echogenicity indices for the CN, LN, insula, and BR with optimal sensitivity and specificity were calculated using receiver operating characteristic analysis. Results: The mean echogenicity indices for the CN (67.0±22.6 vs. 37.9±7.6, p<0.0001), LN (110.7±23.6 vs. 59.7±11.1, p<0.0001), and insula (121.7±39.1 vs. 70.8±23.0, p<0.0001) were significantly higher in HD patients than in healthy controls. In contrast, BR echogenicity (24.8±5.3 vs. 30.1±5.3, p<0.001) was lower in HD patients than in healthy controls. The area under the curve was 90.9%, 95.5%, 84.1%, and 81.8% for the CN, LN, insula, and BR, respectively. The sensitivity and specificity were 86% and 96%, respectively, for the CN and 90% and 100%, respectively, for the LN. Conclusion: Increased CN, LN, and insula echogenicity and decreased BR echogenicity are typical findings in HD patients. The high sensitivity and specificity of the CN and LN hyperechogenicity in TCS-MR fusion imaging make them promising diagnostic markers for HD.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30210 - Clinical neurology
Návaznosti výsledku
Projekt
<a href="/cs/project/LX22NPO5107" target="_blank" >LX22NPO5107: Národní ústav pro neurologický výzkum</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ultraschall in der Medizin
ISSN
0172-4614
e-ISSN
1438-8782
Svazek periodika
44
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
495-502
Kód UT WoS článku
000992933900001
EID výsledku v databázi Scopus
2-s2.0-85190320355