Transnasal endoscopic pituitary surgery - the role of a CT scan in individual tailoring of posterior septum size resection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F23%3AE0110582" target="_blank" >RIV/00843989:_____/23:E0110582 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2379-139X/9/6/172" target="_blank" >https://www.mdpi.com/2379-139X/9/6/172</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/tomography9060172" target="_blank" >10.3390/tomography9060172</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Transnasal endoscopic pituitary surgery - the role of a CT scan in individual tailoring of posterior septum size resection
Popis výsledku v původním jazyce
Objective: This study was designed to evaluate the possibility of predicting the minimum size of septal resection for safe tumor extraction in transnasal paraseptal pituitary adenoma resection from preoperative computed tomography scans. Methods: A retrospective CT scan analysis was performed on 20 patients who underwent endoscopic pituitary surgery at the University Hospital in Ostrava. Virtual insertion of the straight instrument into the sphenoid cavity was simulated using a CT scan. The minimum septal resection size was predicted and compared to various diameters in the nasal cavity. The results were then compared with cadaveric dissections, in which septal resections were performed at 1 cm and 2 cm distances from the anterior sphenoid wall. The association between cadaver dissections and CT scan results was studied. Results: A total of 20 patients who underwent endoscopic transnasal surgery for pituitary adenoma between the years 2020 and 2021 were enrolled in the study. The mean virtual posterior septal size resection needed to reach the medial edge of the ICA with the straight instrument, without infracturing the nasal septum, was 13.2 mm. In cadavers with a 1 cm posterior septal resection, the medial edge of the ICA was reached with the straight instrument. In 2 cm resections, it was possible to reach beyond the lateral edge of the ICA. Conclusion: There is no significant correlation between the minimum septal size resection and measured diameters in the nasal cavity. According to our study, a 1 cm resection is sufficient for a non-extended pituitary tumor extraction. More extensive septal resections allow for better maneuverability and overview in the surgical field.
Název v anglickém jazyce
Transnasal endoscopic pituitary surgery - the role of a CT scan in individual tailoring of posterior septum size resection
Popis výsledku anglicky
Objective: This study was designed to evaluate the possibility of predicting the minimum size of septal resection for safe tumor extraction in transnasal paraseptal pituitary adenoma resection from preoperative computed tomography scans. Methods: A retrospective CT scan analysis was performed on 20 patients who underwent endoscopic pituitary surgery at the University Hospital in Ostrava. Virtual insertion of the straight instrument into the sphenoid cavity was simulated using a CT scan. The minimum septal resection size was predicted and compared to various diameters in the nasal cavity. The results were then compared with cadaveric dissections, in which septal resections were performed at 1 cm and 2 cm distances from the anterior sphenoid wall. The association between cadaver dissections and CT scan results was studied. Results: A total of 20 patients who underwent endoscopic transnasal surgery for pituitary adenoma between the years 2020 and 2021 were enrolled in the study. The mean virtual posterior septal size resection needed to reach the medial edge of the ICA with the straight instrument, without infracturing the nasal septum, was 13.2 mm. In cadavers with a 1 cm posterior septal resection, the medial edge of the ICA was reached with the straight instrument. In 2 cm resections, it was possible to reach beyond the lateral edge of the ICA. Conclusion: There is no significant correlation between the minimum septal size resection and measured diameters in the nasal cavity. According to our study, a 1 cm resection is sufficient for a non-extended pituitary tumor extraction. More extensive septal resections allow for better maneuverability and overview in the surgical field.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Tomography
ISSN
2379-139X
e-ISSN
2379-139X
Svazek periodika
9
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
11
Strana od-do
2222-2232
Kód UT WoS článku
001130863100001
EID výsledku v databázi Scopus
2-s2.0-85180690068