Design and testing of a device for human limb multifrequency comparative bioimpedance measurement - preliminary study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F23%3AE0110922" target="_blank" >RIV/00843989:_____/23:E0110922 - isvavai.cz</a>
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/9511" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/9511</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2023.1.05" target="_blank" >10.14311/CTJ.2023.1.05</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design and testing of a device for human limb multifrequency comparative bioimpedance measurement - preliminary study
Popis výsledku v původním jazyce
Bioimpedance is the ability of biological tissues to impede the flow of electrical current. It is often measured as a means of detecting volume and structural changes in various biological tissues. The purpose of this work was to design a two-channel portable device for measuring multifrequency bioimpedance of human limbs. The device was constructed specifically for evaluation of the bioimpedance measurement as a possible tool for aiding in diagnosis of soft-tissue structural changes in the muscles of human limbs by continuously comparing bioimpedance of one limb to the other. The proposed device is based on impedance converter AD5933. It is designed for noninvasive measurements on the human body with low amplitude alternating current at frequencies between 1 kHz and 100 kHz. The device was tested for electromagnetic compatibility, accuracy and used in laboratory measurements for detection of muscle edema on a bioimpedance model. It is capable of measuring impedance up to 100 k? with a relative measurement error below 1.84%.
Název v anglickém jazyce
Design and testing of a device for human limb multifrequency comparative bioimpedance measurement - preliminary study
Popis výsledku anglicky
Bioimpedance is the ability of biological tissues to impede the flow of electrical current. It is often measured as a means of detecting volume and structural changes in various biological tissues. The purpose of this work was to design a two-channel portable device for measuring multifrequency bioimpedance of human limbs. The device was constructed specifically for evaluation of the bioimpedance measurement as a possible tool for aiding in diagnosis of soft-tissue structural changes in the muscles of human limbs by continuously comparing bioimpedance of one limb to the other. The proposed device is based on impedance converter AD5933. It is designed for noninvasive measurements on the human body with low amplitude alternating current at frequencies between 1 kHz and 100 kHz. The device was tested for electromagnetic compatibility, accuracy and used in laboratory measurements for detection of muscle edema on a bioimpedance model. It is capable of measuring impedance up to 100 k? with a relative measurement error below 1.84%.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
2336-5552
Svazek periodika
53
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
25-31
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85191733321