Dynamic myocardial perfusion SPECT: Prognostic value of myocardial stress blood flow and coronary flow reserve quantification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F25%3AE0112050" target="_blank" >RIV/00843989:_____/25:E0112050 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/25:00142121 RIV/61988987:17110/25:A2603DPY RIV/61989592:15110/25:73632853 RIV/00098892:_____/25:10159626 RIV/00159816:_____/25:00082319
Výsledek na webu
<a href="https://journals.viamedica.pl/polish_heart_journal/article/view/108516/84739" target="_blank" >https://journals.viamedica.pl/polish_heart_journal/article/view/108516/84739</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33963/v.phj.108516" target="_blank" >10.33963/v.phj.108516</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dynamic myocardial perfusion SPECT: Prognostic value of myocardial stress blood flow and coronary flow reserve quantification
Popis výsledku v původním jazyce
Positron emission tomography (PET) remains the gold standard for measuring myocardial blood flow (MBF) and coronary flow reserve (CFR), but it requires an on-site cyclotron or costly generator for the production of PET perfusion tracers. In recent years, several studies have had good agreement in the calculation of MBF and CFR, confirming the feasibility and reproducibility, as well as good agreement between PET and single photon emission computed tomography (SPECT) using dedicated cadmium-zinc-telluride (CZT) tomographic 3 cameras. However, the great disadvantage of the typical dynamic SPECT protocol is its complexity, with a greater radiation burden, cost, and acquisition time. The aim of this study was to compare the prognostic significance of stress (strMBF), CFR, and assess the potential of a strMBF-only protocol.
Název v anglickém jazyce
Dynamic myocardial perfusion SPECT: Prognostic value of myocardial stress blood flow and coronary flow reserve quantification
Popis výsledku anglicky
Positron emission tomography (PET) remains the gold standard for measuring myocardial blood flow (MBF) and coronary flow reserve (CFR), but it requires an on-site cyclotron or costly generator for the production of PET perfusion tracers. In recent years, several studies have had good agreement in the calculation of MBF and CFR, confirming the feasibility and reproducibility, as well as good agreement between PET and single photon emission computed tomography (SPECT) using dedicated cadmium-zinc-telluride (CZT) tomographic 3 cameras. However, the great disadvantage of the typical dynamic SPECT protocol is its complexity, with a greater radiation burden, cost, and acquisition time. The aim of this study was to compare the prognostic significance of stress (strMBF), CFR, and assess the potential of a strMBF-only protocol.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Kardiologia Polska
ISSN
0022-9032
e-ISSN
1897-4279
Svazek periodika
83
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
3
Strana od-do
1331-1333
Kód UT WoS článku
001636256600001
EID výsledku v databázi Scopus
—