Constructed wetland Libnič Typical example of a constructed wetland used in the Czech Republic for wastewater treatment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25173154%3A_____%2F10%3A%230000155" target="_blank" >RIV/25173154:_____/10:#0000155 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Constructed wetland Libnič Typical example of a constructed wetland used in the Czech Republic for wastewater treatment
Popis výsledku v původním jazyce
Constructed wetland Libnič for 500 PE was put in operation in 2006. It is a typical horizontal subsurface flow system designed to treat municipal wastewater in the Czech Republic. During the period 2008-2009, the treatment performance and evapotranspiration were regularly monitored. The average treatment effects for BOD5, COD and TSS were 71%, 50% and 89%, respectively. The average outflow BOD5, COD and TSS concentrations during the monitored period were 10.7 mg l-1, 48.9 mg l-1 and 5.4 mg l-1, respectively. Removal of TN and TP amounted to 36% and 19%, with respective average outflow concentrations of 17.1 mg l-1 and 2.5 mg l-1. These results are commonly achieved in horizontal subsurface constructed wetlands. In July 2008, inflow and outflow ultrasonic sensors for wastewater flow measurement were installed. A weather station was installed in middle of the first filtration bed and it continuously recorded the following parameters: temperature, humidity, precipitation and global radiat
Název v anglickém jazyce
Constructed wetland Libnič Typical example of a constructed wetland used in the Czech Republic for wastewater treatment
Popis výsledku anglicky
Constructed wetland Libnič for 500 PE was put in operation in 2006. It is a typical horizontal subsurface flow system designed to treat municipal wastewater in the Czech Republic. During the period 2008-2009, the treatment performance and evapotranspiration were regularly monitored. The average treatment effects for BOD5, COD and TSS were 71%, 50% and 89%, respectively. The average outflow BOD5, COD and TSS concentrations during the monitored period were 10.7 mg l-1, 48.9 mg l-1 and 5.4 mg l-1, respectively. Removal of TN and TP amounted to 36% and 19%, with respective average outflow concentrations of 17.1 mg l-1 and 2.5 mg l-1. These results are commonly achieved in horizontal subsurface constructed wetlands. In July 2008, inflow and outflow ultrasonic sensors for wastewater flow measurement were installed. A weather station was installed in middle of the first filtration bed and it continuously recorded the following parameters: temperature, humidity, precipitation and global radiat
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2B06023" target="_blank" >2B06023: Vývoj metody stanovení toků energie a látek ve vybraných ekosystémech, návrh a ověření principů hodnocení hospodářských zásahů pro zajištění podmínek autoregulace a rozvoje biodiverzity</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Wetland Systems for Water Pollution Kontrol
ISBN
978-88-6060-300-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IWA
Místo vydání
Venice
Místo konání akce
Venice
Datum konání akce
4. 10. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—