Single crystal scintillator plates used for light weight material X-ray radiography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25296558%3A_____%2F13%3A%230000053" target="_blank" >RIV/25296558:_____/13:#0000053 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Single crystal scintillator plates used for light weight material X-ray radiography
Popis výsledku v původním jazyce
Very thin scintillator imaging plates have recently become of great interest. In high resolution X-ray projection imaging, very thin scintillators of about 5-20 micrometres are used to achieve high spatial resolution. Such thin screens are mainly used inmicro-CT and nano-CT systems with either micro-focus X-ray tubes or with synchrotron sources. This work deals with a high resolution CCD camera in connection with an optical system and different single crystal scintillators in application for low energyX-ray micro-radiography. The thin screens used were prepared by mechanical polishing from Y3Al5O12 or Lu3Al5O12 single crystals. The screens can be used in equipment for the detection of different kinds of radiation and particles (UV, VUV, electrons orions or their beams, X- or gamma-rays). A high resolution open type micro-focus X-ray tube was used to achieve the high resolution. The results show that the single crystal plates exhibit high spatial resolution and high sensitivity to lo
Název v anglickém jazyce
Single crystal scintillator plates used for light weight material X-ray radiography
Popis výsledku anglicky
Very thin scintillator imaging plates have recently become of great interest. In high resolution X-ray projection imaging, very thin scintillators of about 5-20 micrometres are used to achieve high spatial resolution. Such thin screens are mainly used inmicro-CT and nano-CT systems with either micro-focus X-ray tubes or with synchrotron sources. This work deals with a high resolution CCD camera in connection with an optical system and different single crystal scintillators in application for low energyX-ray micro-radiography. The thin screens used were prepared by mechanical polishing from Y3Al5O12 or Lu3Al5O12 single crystals. The screens can be used in equipment for the detection of different kinds of radiation and particles (UV, VUV, electrons orions or their beams, X- or gamma-rays). A high resolution open type micro-focus X-ray tube was used to achieve the high resolution. The results show that the single crystal plates exhibit high spatial resolution and high sensitivity to lo
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010164" target="_blank" >TA01010164: Pokročilé techniky detekce ionizujícího záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Physics: Conference Series
ISSN
1742-6596
e-ISSN
—
Svazek periodika
2013
Číslo periodika v rámci svazku
425
Stát vydavatele periodika
VG - Britské Panenské ostrovy
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—