The evaluation of corrosion damage of galvanized tubes for hot water distribution
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25794787%3A_____%2F10%3A%230000235" target="_blank" >RIV/25794787:_____/10:#0000235 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The evaluation of corrosion damage of galvanized tubes for hot water distribution
Popis výsledku v původním jazyce
Property damage caused by failure of pipe systems are very serious from point of view of insurance companies and the reasons of failure of distribution systems made from metallic materials may be the unsuitable design, assembly or operation of system. New distribution systems are usually equipped by automatic heating exchangers and water temperature is relatively exactly controlled at range 50 ? 55?C even for decreasing the energy cost. On the contrary the water chemistry is analysed only sporadically.The cross sections of galvanised tubes in various stages of corrosion attack had been done together with corrosion products analysis. The performed test showed the effect of water chemistry has significant influence on corrosion of galvanized steel and that this effect increased with increasing temperature.
Název v anglickém jazyce
The evaluation of corrosion damage of galvanized tubes for hot water distribution
Popis výsledku anglicky
Property damage caused by failure of pipe systems are very serious from point of view of insurance companies and the reasons of failure of distribution systems made from metallic materials may be the unsuitable design, assembly or operation of system. New distribution systems are usually equipped by automatic heating exchangers and water temperature is relatively exactly controlled at range 50 ? 55?C even for decreasing the energy cost. On the contrary the water chemistry is analysed only sporadically.The cross sections of galvanised tubes in various stages of corrosion attack had been done together with corrosion products analysis. The performed test showed the effect of water chemistry has significant influence on corrosion of galvanized steel and that this effect increased with increasing temperature.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JK - Koroze a povrchové úpravy materiálu
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F560" target="_blank" >FR-TI1/560: Optimalizace výrobních a provozních podmínek žárově zinkovaných trubek pro systémy vnitřního rozvodu vody</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
proceedings of 2nd International conference Corrosion and Material Protection
ISBN
978-80-903933-6-3
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
SVÚOM s. r. o.
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—