Evaluation of depth and profile of surface longitudinal cracks and their growth in DN300 high pressure pipeline
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25797000%3A_____%2F17%3AN0000033" target="_blank" >RIV/25797000:_____/17:N0000033 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of depth and profile of surface longitudinal cracks and their growth in DN300 high pressure pipeline
Popis výsledku v původním jazyce
In an operated DN300 high pressure pipeline, crack-like defects were detected by internal inspection methods. The pipeline section could not be therefore further operated without detailed and careful evaluation of its safety and reliability. Several meters long section of the pipeline was taken out from ground for the purpose of experimental laboratory evaluation of the damage extent. Magnetic defectoscopy confirmed an existence of numerous distinct indications of longitudinal defects. Methodology of measurement of depth of these cracks was proposed using direct current potential drop (DCPD) method. An experimental calibration dependence of potentials on crack depth and shape was evaluated in laboratory. Precision limits of the DCPD method being used in this specific case are discussed in the paper, particularly considering inclined shape of the cracks. Results are related to actual crack depth values and their inclination evaluated by metallographic method.
Název v anglickém jazyce
Evaluation of depth and profile of surface longitudinal cracks and their growth in DN300 high pressure pipeline
Popis výsledku anglicky
In an operated DN300 high pressure pipeline, crack-like defects were detected by internal inspection methods. The pipeline section could not be therefore further operated without detailed and careful evaluation of its safety and reliability. Several meters long section of the pipeline was taken out from ground for the purpose of experimental laboratory evaluation of the damage extent. Magnetic defectoscopy confirmed an existence of numerous distinct indications of longitudinal defects. Methodology of measurement of depth of these cracks was proposed using direct current potential drop (DCPD) method. An experimental calibration dependence of potentials on crack depth and shape was evaluated in laboratory. Precision limits of the DCPD method being used in this specific case are discussed in the paper, particularly considering inclined shape of the cracks. Results are related to actual crack depth values and their inclination evaluated by metallographic method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Proceeding
ISBN
978-802610624-1
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
Department of Mechanics, Faculty of Applied Sciences, University of West Bohemia
Místo vydání
Plzeň
Místo konání akce
Srní
Datum konání akce
30. 5. 2016
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—