Structural Degradation of Steam Pipe Bend made of 0.5Cr-0.5MO-0.3V Steel after Long-term Creep Exposure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25870807%3A_____%2F15%3A%230000447" target="_blank" >RIV/25870807:_____/15:#0000447 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.metal2016.com/cz/sbornik-konference-metal-2015/" target="_blank" >http://www.metal2016.com/cz/sbornik-konference-metal-2015/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Structural Degradation of Steam Pipe Bend made of 0.5Cr-0.5MO-0.3V Steel after Long-term Creep Exposure
Popis výsledku v původním jazyce
A creep damaged area was found during the routine control of the steam pipeline bend of 200 MW fossil-fuelled power plant boiler close to the outer fibre and near the top of the bend. The damaged area with identified creep cracks was about 250 x 600 mm in size and the maximum depth of the cracks was 7 mm. Metallographic analysis carried out in this area confirmed the non-homogeneous cavitation damage. Density of cavities continuously decreased throughout the affected area from the outer to the inner surface of the pipe, around the pipe circumference and also in the axial direction along the length of the bend. The actual extent of degradation of material properties was then evaluated by testing the mechanical properties, notch and fracture toughness and the results were used to calculate the residual life of the bend. The results of these analyses showed that although the creep damage extent was probably one of the worst, which had been ever detected in the boiler of this type, cracks
Název v anglickém jazyce
Structural Degradation of Steam Pipe Bend made of 0.5Cr-0.5MO-0.3V Steel after Long-term Creep Exposure
Popis výsledku anglicky
A creep damaged area was found during the routine control of the steam pipeline bend of 200 MW fossil-fuelled power plant boiler close to the outer fibre and near the top of the bend. The damaged area with identified creep cracks was about 250 x 600 mm in size and the maximum depth of the cracks was 7 mm. Metallographic analysis carried out in this area confirmed the non-homogeneous cavitation damage. Density of cavities continuously decreased throughout the affected area from the outer to the inner surface of the pipe, around the pipe circumference and also in the axial direction along the length of the bend. The actual extent of degradation of material properties was then evaluated by testing the mechanical properties, notch and fracture toughness and the results were used to calculate the residual life of the bend. The results of these analyses showed that although the creep damage extent was probably one of the worst, which had been ever detected in the boiler of this type, cracks
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1203" target="_blank" >LO1203: Regionální materiálově technologické výzkumné centrum - Program udržitelnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
24. ročník mezinárodní konference metalurgie a materiálů METAL 2015
ISBN
978-80-87294-58-1
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
742-749
Název nakladatele
Tanger,s.r.o.
Místo vydání
Brno
Místo konání akce
Hotel Voroněž, Brno
Datum konání akce
3. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—