Small punch test - Two methods of TSP temperature determination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25870807%3A_____%2F21%3AN0000004" target="_blank" >RIV/25870807:_____/21:N0000004 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.37904/metal.2021.4158" target="_blank" >https://doi.org/10.37904/metal.2021.4158</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.37904/metal.2021.4158" target="_blank" >10.37904/metal.2021.4158</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Small punch test - Two methods of TSP temperature determination
Popis výsledku v původním jazyce
The paper deals with comparison of two methods for determination of TSP temperature used to evaluate DBTT. The historically used two-curve method relies on two distinctive energies - the fracture energy at the zero-point of the absolute temperature, that is determined by extrapolating the fitted function for the lower shelf, and the fracture energy at the intersection point between the fits for the lower and upper shelves. The method preferred by new standards calculates TSP temperature by fitting a tangential function in the similar way as various formulas used for evaluation of Charpy tests. Presented paper deals with the evaluation of TSP temperature in P91 pipes by both methods. The effect of using both 2 mm and 2.5 mm diameter punches is assessed too.
Název v anglickém jazyce
Small punch test - Two methods of TSP temperature determination
Popis výsledku anglicky
The paper deals with comparison of two methods for determination of TSP temperature used to evaluate DBTT. The historically used two-curve method relies on two distinctive energies - the fracture energy at the zero-point of the absolute temperature, that is determined by extrapolating the fitted function for the lower shelf, and the fracture energy at the intersection point between the fits for the lower and upper shelves. The method preferred by new standards calculates TSP temperature by fitting a tangential function in the similar way as various formulas used for evaluation of Charpy tests. Presented paper deals with the evaluation of TSP temperature in P91 pipes by both methods. The effect of using both 2 mm and 2.5 mm diameter punches is assessed too.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TK01020160" target="_blank" >TK01020160: Komplexní postupy materiálového inženýrství k zajištění bezpečného provozu inovovaných bloků klasických elektráren.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Metal 2021 - 30th Anniversary International Conference on Metallurgy and Materials
ISBN
978-80-87294-99-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
556-561
Název nakladatele
Tanger, s.r.o.
Místo vydání
Ostrava
Místo konání akce
Brno, Virtual
Datum konání akce
26. 5. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce