Determination of Solidus nad Liquidus Temperatures for 20MnMoNi5-5 Steel Grade by Thermal Analysis Methods and by Calculations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F25877950%3A_____%2F13%3A%230000065" target="_blank" >RIV/25877950:_____/13:#0000065 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Solidus nad Liquidus Temperatures for 20MnMoNi5-5 Steel Grade by Thermal Analysis Methods and by Calculations
Popis výsledku v původním jazyce
The paper is devoted to the determination of solidus and liquidus temperatures obtained by thermo-analytical methods and by the generally used empirically based formulas and thermo dynamical Computherm software. The series of thermal analysis measurements of high temperature phase transformations of real steel grade (20MnMoNi5-5) under conditions of two analytical devices (Netzsch STA 449 F3 Jupiter; Setaram Multi High Temperature Calorimeter (MHTC)) were carried out. Two thermo-analytical methods wereused (DSC and Direct Thermal Analysis). Different weight of samples was used (2,6 g; 23 g). The liquidus and solidus temperatures for close to equilibrium conditions during heating (DSC: 1 °C/min; 2 °C/min) and during cooling (Direct Thermal Analysis: 1°C/min) were determined and compared. Then, the different values obtained by experiments and empirically based calculation were discussed.
Název v anglickém jazyce
Determination of Solidus nad Liquidus Temperatures for 20MnMoNi5-5 Steel Grade by Thermal Analysis Methods and by Calculations
Popis výsledku anglicky
The paper is devoted to the determination of solidus and liquidus temperatures obtained by thermo-analytical methods and by the generally used empirically based formulas and thermo dynamical Computherm software. The series of thermal analysis measurements of high temperature phase transformations of real steel grade (20MnMoNi5-5) under conditions of two analytical devices (Netzsch STA 449 F3 Jupiter; Setaram Multi High Temperature Calorimeter (MHTC)) were carried out. Two thermo-analytical methods wereused (DSC and Direct Thermal Analysis). Different weight of samples was used (2,6 g; 23 g). The liquidus and solidus temperatures for close to equilibrium conditions during heating (DSC: 1 °C/min; 2 °C/min) and during cooling (Direct Thermal Analysis: 1°C/min) were determined and compared. Then, the different values obtained by experiments and empirically based calculation were discussed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI3%2F243" target="_blank" >FR-TI3/243: *Experimentální vývoj a optimalizace výrobní technologie těžkých kovářských ingotů s cílem zlepšení užitných vlastností speciálních strojních součástí s vyšší přidanou hodnotou</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Hutnické listy
ISSN
0018-8069
e-ISSN
—
Svazek periodika
66
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
64-68
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—