Filler from expanded glass as a light-weighing component of the cement composite with fiber reinforcement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26232511%3A_____%2F14%3ALEVLAK29" target="_blank" >RIV/26232511:_____/14:LEVLAK29 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1000.102" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMR.1000.102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMR.1000.102" target="_blank" >10.4028/www.scientific.net/AMR.1000.102</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Filler from expanded glass as a light-weighing component of the cement composite with fiber reinforcement
Popis výsledku v původním jazyce
Bulk density reduction of the cement composite is possible by the means of using suitable light fillers in a matrix or porous structure creation with an air-entraining agent. Both ways are more or less suitable or effective for proper parameter achievement. From the range of possible fillers with different material properties and influence on rheological parameters during production granulated expanded glass worked the best. By the means of laboratory testing an effect of two fillers based on expanded glass on the fiber reinforced cement composite was verified. Practical applicability was tested in the production of commonly manufactured glass fiber reinforced concrete elements, such as channels for electrical cable deposition and products for urban equipment.
Název v anglickém jazyce
Filler from expanded glass as a light-weighing component of the cement composite with fiber reinforcement
Popis výsledku anglicky
Bulk density reduction of the cement composite is possible by the means of using suitable light fillers in a matrix or porous structure creation with an air-entraining agent. Both ways are more or less suitable or effective for proper parameter achievement. From the range of possible fillers with different material properties and influence on rheological parameters during production granulated expanded glass worked the best. By the means of laboratory testing an effect of two fillers based on expanded glass on the fiber reinforced cement composite was verified. Practical applicability was tested in the production of commonly manufactured glass fiber reinforced concrete elements, such as channels for electrical cable deposition and products for urban equipment.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F404" target="_blank" >FR-TI1/404: Lehké vláknocementové kompozitní dílce</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Materials Research
ISSN
1022-6680
e-ISSN
—
Svazek periodika
Vol. 1000
Číslo periodika v rámci svazku
2014
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
102-105