The influence of ventilated façade on sound insulation properties of envelope walls
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26232511%3A_____%2F16%3AN0000052" target="_blank" >RIV/26232511:_____/16:N0000052 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26110/16:PU124630
Výsledek na webu
<a href="http://www.matec-conferences.org/articles/matecconf/pdf/2017/07/matecconf_bd2017_03003.pdf" target="_blank" >http://www.matec-conferences.org/articles/matecconf/pdf/2017/07/matecconf_bd2017_03003.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/https://doi.org/10.1051/matecconf/201779303003" target="_blank" >https://doi.org/10.1051/matecconf/201779303003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of ventilated façade on sound insulation properties of envelope walls
Popis výsledku v původním jazyce
Presented article deals with sound insulation properties of timber structures’ envelope walls. Particularly, the influence of heavy board ventilated façade on laboratory airborne sound insulation R and Rw in dB was studied. The installation method and gaps between façade boards can cause building defects originating in overrating the influence of ventilated cladding on envelope wall acoustic parameters. Real constructions were built for the experimental purposes and measurements, one with gaps between boards and one with simply eliminated gaps for mutual comparison. The results obtained were processed to make tables and graphs and to derive recommendations for the design of this type of constructions involving the general installation method of façade boards. Detailed results are depicted in conclusions.
Název v anglickém jazyce
The influence of ventilated façade on sound insulation properties of envelope walls
Popis výsledku anglicky
Presented article deals with sound insulation properties of timber structures’ envelope walls. Particularly, the influence of heavy board ventilated façade on laboratory airborne sound insulation R and Rw in dB was studied. The installation method and gaps between façade boards can cause building defects originating in overrating the influence of ventilated cladding on envelope wall acoustic parameters. Real constructions were built for the experimental purposes and measurements, one with gaps between boards and one with simply eliminated gaps for mutual comparison. The results obtained were processed to make tables and graphs and to derive recommendations for the design of this type of constructions involving the general installation method of façade boards. Detailed results are depicted in conclusions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JN - Stavebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
8th International Scientific Conference Building Defects (Building Defects 2016)
ISBN
978-2-7598-9012-5
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
nestrankovano
Název nakladatele
EDP Sciences
Místo vydání
—
Místo konání akce
České Budějovice
Datum konání akce
24. 11. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce