Correction in determination of specific activity of radionuclides by gamma spectrometry in building materials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26232511%3A_____%2F20%3AN0000049" target="_blank" >RIV/26232511:_____/20:N0000049 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1757-899X/1039/1/012022/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1757-899X/1039/1/012022/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/1039/1/012022" target="_blank" >10.1088/1757-899X/1039/1/012022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correction in determination of specific activity of radionuclides by gamma spectrometry in building materials
Popis výsledku v původním jazyce
For more accurate determination of specific activities of radionuclides by gamma spectrometry in materials, it is necessary to take into account two important factors. These are the effect of true coincidences and self-absorption of gamma radiation directly in the measured sample. The corrections for these factors are determined for the specific measurement geometry defined by the detector, the measuring vessel and their relative positions. Corrections are calculated by Monte Carlo simulation. The results show a significant effect of material bulk density on the correction values.
Název v anglickém jazyce
Correction in determination of specific activity of radionuclides by gamma spectrometry in building materials
Popis výsledku anglicky
For more accurate determination of specific activities of radionuclides by gamma spectrometry in materials, it is necessary to take into account two important factors. These are the effect of true coincidences and self-absorption of gamma radiation directly in the measured sample. The corrections for these factors are determined for the specific measurement geometry defined by the detector, the measuring vessel and their relative positions. Corrections are calculated by Monte Carlo simulation. The results show a significant effect of material bulk density on the correction values.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20500 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IOP Conference Series: Materials Science and Engineering
ISSN
17578981
e-ISSN
1757-899X
Svazek periodika
—
Číslo periodika v rámci svazku
1039(1)
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1-8
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85101645261