Calibration of Selected Ductile Fracture Criteria Using Two Types of Specimens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26316919%3A_____%2F13%3A%230000477" target="_blank" >RIV/26316919:_____/13:#0000477 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.scientific.net/KEM.592-593.258" target="_blank" >http://www.scientific.net/KEM.592-593.258</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.592-593.258" target="_blank" >10.4028/www.scientific.net/KEM.592-593.258</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration of Selected Ductile Fracture Criteria Using Two Types of Specimens
Popis výsledku v původním jazyce
This paper presents the calibration of three universal ductile fracture criteria with the stress triaxiality and the normalized third invariant of deviatoric stress dependence. Xue-Wierzbicki, Bai-Wierzbicki and Extended Mohr-Coulomb criteria are calibrated using butterfly specimen and newly designed notched tube specimen for an austenitic stainless steel. Different stress states necessary for successful calibration are generated by suitable combination of tension/compression-shear or tension/compression-torsion loading of both specimens, respectively. Suitability of the specimens for ductile fracture criteria calibration is evaluated comparing the range of reached stress states, the homogeneity of stress in process zone and appropriateness for the computational simulation of tests. Possible combination of above mentioned results with tensile testing of standard and notched cylindrical specimens is discussed, too.
Název v anglickém jazyce
Calibration of Selected Ductile Fracture Criteria Using Two Types of Specimens
Popis výsledku anglicky
This paper presents the calibration of three universal ductile fracture criteria with the stress triaxiality and the normalized third invariant of deviatoric stress dependence. Xue-Wierzbicki, Bai-Wierzbicki and Extended Mohr-Coulomb criteria are calibrated using butterfly specimen and newly designed notched tube specimen for an austenitic stainless steel. Different stress states necessary for successful calibration are generated by suitable combination of tension/compression-shear or tension/compression-torsion loading of both specimens, respectively. Suitability of the specimens for ductile fracture criteria calibration is evaluated comparing the range of reached stress states, the homogeneity of stress in process zone and appropriateness for the computational simulation of tests. Possible combination of above mentioned results with tensile testing of standard and notched cylindrical specimens is discussed, too.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI2%2F279" target="_blank" >FR-TI2/279: *Identifikace parametrů tvárného porušení materiálů jaderných zařízení</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Key Engineering Materials
ISSN
1662-9795
e-ISSN
—
Svazek periodika
592-593
Číslo periodika v rámci svazku
11/2013
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
258-261
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—