Technological aspects of preparation of nanostructured titanium wire using a CONFORM machine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26316919%3A_____%2F14%3A%230000595" target="_blank" >RIV/26316919:_____/14:#0000595 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/63/1/012049" target="_blank" >http://dx.doi.org/10.1088/1757-899X/63/1/012049</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/63/1/012049" target="_blank" >10.1088/1757-899X/63/1/012049</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Technological aspects of preparation of nanostructured titanium wire using a CONFORM machine
Popis výsledku v původním jazyce
One of available ways to enhancing the efficiency of production of sections is combining the CONFORM continuous extrusion process and the ECAP method. This paper describes the initial experience with such a combined process deployed in the CONFORM 315i machine, which is equipped with a specially-designed die chamber. Process trials were performed to explore the effects of the set-up of the CONFORM equipment on the resulting microstructure of Ti wire. The feedstock was in the form of CP Ti grade 2 bars of 10 mm diameter. Crucial parameters of the process include the temperature of the die chamber, which was purposefully varied from the initial 500 degrees C to the final 200 degrees C, and the cooling stage, which was realized immediately upon the exit from the die chamber. The mean grain size, mechanical properties and thermal stability were measured and studied in the specimens upon forming. The smallest grain size was achieved by two passes at 200 degrees C.
Název v anglickém jazyce
Technological aspects of preparation of nanostructured titanium wire using a CONFORM machine
Popis výsledku anglicky
One of available ways to enhancing the efficiency of production of sections is combining the CONFORM continuous extrusion process and the ECAP method. This paper describes the initial experience with such a combined process deployed in the CONFORM 315i machine, which is equipped with a specially-designed die chamber. Process trials were performed to explore the effects of the set-up of the CONFORM equipment on the resulting microstructure of Ti wire. The feedstock was in the form of CP Ti grade 2 bars of 10 mm diameter. Crucial parameters of the process include the temperature of the die chamber, which was purposefully varied from the initial 500 degrees C to the final 200 degrees C, and the cooling stage, which was realized immediately upon the exit from the die chamber. The mean grain size, mechanical properties and thermal stability were measured and studied in the specimens upon forming. The smallest grain size was achieved by two passes at 200 degrees C.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
6TH INTERNATIONAL CONFERENCE ON NANOMATERIALS BY SEVERE PLASTIC DEFORMATION (NANOSPD6)
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
IOP Publishing
Místo vydání
Bristol
Místo konání akce
Metz
Datum konání akce
30. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—