IAEA coordinated research project on master curve approach to monitor fracture toughness of RPV steels: Final results of the experimental exercise to support constraint effects
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F10%3A%230000748" target="_blank" >RIV/26722445:_____/10:#0000748 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
IAEA coordinated research project on master curve approach to monitor fracture toughness of RPV steels: Final results of the experimental exercise to support constraint effects
Popis výsledku v původním jazyce
The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, To, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the To temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [ITC(T)], generally considered the standard reference specimen for To. This difference in To has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen.
Název v anglickém jazyce
IAEA coordinated research project on master curve approach to monitor fracture toughness of RPV steels: Final results of the experimental exercise to support constraint effects
Popis výsledku anglicky
The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, To, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the To temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [ITC(T)], generally considered the standard reference specimen for To. This difference in To has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ASME pressure vessels and piping conference 2009, Vol 3: design and analysis
ISBN
978-0-7918-4366-6
ISSN
—
e-ISSN
—
Počet stran výsledku
13
Strana od-do
573-585