Photon Spectrum behind Biological Shielding of the LVR-15 Research Reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F12%3A%230000705" target="_blank" >RIV/26722445:_____/12:#0000705 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1520/JAI104077" target="_blank" >http://dx.doi.org/10.1520/JAI104077</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1520/JAI104077" target="_blank" >10.1520/JAI104077</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photon Spectrum behind Biological Shielding of the LVR-15 Research Reactor
Popis výsledku v původním jazyce
The LVR-15 reactor is a light water research reactor situated at the Research Centre Řež, near Prague. It operates as a multipurpose facility with a maximum thermal power of 10 MW. The reactor core usually contains from 28 to 32 fuel assemblies with a total mass of 235U of about 5 kg. Emitted radiation from the fuel caused by fission is shielded by moderating water, a steel reactor vessel, and heavy concrete. This paper deals with measurement and analysis of the gamma spectrum near the outer surface ofthe concrete wall, behind biological shielding, mainly in the 3- to 10-MeV energy range. A portable HPGe detector with a portable multichannel analyzer was used to measure gamma spectra. The origin of energy lines in gamma detector spectra was identified.
Název v anglickém jazyce
Photon Spectrum behind Biological Shielding of the LVR-15 Research Reactor
Popis výsledku anglicky
The LVR-15 reactor is a light water research reactor situated at the Research Centre Řež, near Prague. It operates as a multipurpose facility with a maximum thermal power of 10 MW. The reactor core usually contains from 28 to 32 fuel assemblies with a total mass of 235U of about 5 kg. Emitted radiation from the fuel caused by fission is shielded by moderating water, a steel reactor vessel, and heavy concrete. This paper deals with measurement and analysis of the gamma spectrum near the outer surface ofthe concrete wall, behind biological shielding, mainly in the 3- to 10-MeV energy range. A portable HPGe detector with a portable multichannel analyzer was used to measure gamma spectra. The origin of energy lines in gamma detector spectra was identified.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of ASTM International
ISSN
1546-962X
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
1-5
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—