The Influence of changes in Iron Cross section in the thermal region between CENDL-3.1 and ENDF/B-VII.0
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F14%3A%230000933" target="_blank" >RIV/26722445:_____/14:#0000933 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/14:00310496
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nds.2014.04.135" target="_blank" >http://dx.doi.org/10.1016/j.nds.2014.04.135</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nds.2014.04.135" target="_blank" >10.1016/j.nds.2014.04.135</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Influence of changes in Iron Cross section in the thermal region between CENDL-3.1 and ENDF/B-VII.0
Popis výsledku v původním jazyce
Gamma dose and thermal neutron fluence in a phantom exposed to an epithermal neutron beam for boron neutron capture therapy (BNCT) can be measured by means of a single thermoluminescence dosemeter (TLD-700). The method exploits the shape of the glow curve (GC) and requires the gamma-calibration GC (to obtain gamma dose) and the thermal-neutron-calibration GC (to obtain neutron fluence). The method is applicable for BNCT dosimetry in case of epithermal neutron beams from a reactor because, in most irradiation configurations, thermal neutrons give a not negligible contribution to the TLD-700 GC. The thermal neutron calibration is not simple, because of the impossibility of having thermal neutron fields without gamma contamination, but a calibration method is here proposed, strictly bound to the method itself of dose separation.
Název v anglickém jazyce
The Influence of changes in Iron Cross section in the thermal region between CENDL-3.1 and ENDF/B-VII.0
Popis výsledku anglicky
Gamma dose and thermal neutron fluence in a phantom exposed to an epithermal neutron beam for boron neutron capture therapy (BNCT) can be measured by means of a single thermoluminescence dosemeter (TLD-700). The method exploits the shape of the glow curve (GC) and requires the gamma-calibration GC (to obtain gamma dose) and the thermal-neutron-calibration GC (to obtain neutron fluence). The method is applicable for BNCT dosimetry in case of epithermal neutron beams from a reactor because, in most irradiation configurations, thermal neutrons give a not negligible contribution to the TLD-700 GC. The thermal neutron calibration is not simple, because of the impossibility of having thermal neutron fields without gamma contamination, but a calibration method is here proposed, strictly bound to the method itself of dose separation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0108" target="_blank" >ED2.1.00/03.0108: Udržitelná energetika</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Data Sheets
ISSN
0090-3752
e-ISSN
—
Svazek periodika
118
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
3
Strana od-do
561-563
Kód UT WoS článku
000347704400134
EID výsledku v databázi Scopus
—