HELCZA - High heat flux test facility for testing ITER EU first wall components
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F17%3AN0000011" target="_blank" >RIV/26722445:_____/17:N0000011 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389021:_____/17:00480958
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.fusengdes.2017.03.059" target="_blank" >http://dx.doi.org/10.1016/j.fusengdes.2017.03.059</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.fusengdes.2017.03.059" target="_blank" >10.1016/j.fusengdes.2017.03.059</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HELCZA - High heat flux test facility for testing ITER EU first wall components
Popis výsledku v původním jazyce
The ITER first wall panels are exposed directly to thermonuclear plasma and must extract heat loads of approximately 2 MW/m2 (normal heat flux) to 4.7 MW/m2 (enhanced heat flux). The panels are qualified through high heat flux cyclic testing before installation in ITER. Initially, the first wall panel prototypes will undergo full-power tests, they will be followed by the pre-series panels and finally the series ones. The experimental complex HELCZA (High Energy Load CZech Assembly) has been completed and is currently in the commissioning phase. HELCZA shall be optimised to provide a cyclic heating of the ITER EU first wall panels with a heat flux in the multi-MW/m2 range using an 800 kW electron beam. On a reduced area it is possible to reach GW/m2 scale. Total available test area in HELCZA is 4 m2 depending on the experimental setup. Operational conditions of the HELCZA facility enable the temperature of the cooling water to be set between 25 °C and 320 °C, within a pressure range up to 15 MPa. The cooling system provides an optimal flow rate up to 40 m3/h independent of the pressure.
Název v anglickém jazyce
HELCZA - High heat flux test facility for testing ITER EU first wall components
Popis výsledku anglicky
The ITER first wall panels are exposed directly to thermonuclear plasma and must extract heat loads of approximately 2 MW/m2 (normal heat flux) to 4.7 MW/m2 (enhanced heat flux). The panels are qualified through high heat flux cyclic testing before installation in ITER. Initially, the first wall panel prototypes will undergo full-power tests, they will be followed by the pre-series panels and finally the series ones. The experimental complex HELCZA (High Energy Load CZech Assembly) has been completed and is currently in the commissioning phase. HELCZA shall be optimised to provide a cyclic heating of the ITER EU first wall panels with a heat flux in the multi-MW/m2 range using an 800 kW electron beam. On a reduced area it is possible to reach GW/m2 scale. Total available test area in HELCZA is 4 m2 depending on the experimental setup. Operational conditions of the HELCZA facility enable the temperature of the cooling water to be set between 25 °C and 320 °C, within a pressure range up to 15 MPa. The cooling system provides an optimal flow rate up to 40 m3/h independent of the pressure.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fusion Engineering and Design
ISSN
0920-3796
e-ISSN
1873-7196
Svazek periodika
124
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
187-190
Kód UT WoS článku
000419411900040
EID výsledku v databázi Scopus
2-s2.0-85015782575