Coatings on Steels T91 and 316L in Lead-Bismuth Eutectic Environment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F19%3AN0000091" target="_blank" >RIV/26722445:_____/19:N0000091 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1757-899X/461/1/012028/pdf" target="_blank" >https://iopscience.iop.org/article/10.1088/1757-899X/461/1/012028/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/461/1/012028" target="_blank" >10.1088/1757-899X/461/1/012028</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Coatings on Steels T91 and 316L in Lead-Bismuth Eutectic Environment
Popis výsledku v původním jazyce
The work is aimed on the coatings used as a barrier against Heavy Liquid Metal (HLM) influence and coated material behaviour under mechanical loading. The comparison of two kinds of coatings deposited on two different steels is examined: ferritic-martensitic steel T91 coated with AlTiN and austenitic steel 316L coated with Al2O3. Both samples underwent tensile tests with constant extension rate in the HLM autoclave-cell for material testing. The testing environment in the cell was liquid PbBi eutectic at the temperature of 550 °C. The examination by Scanning electron microscopy and Energy-dispersive X-ray spectroscopy followed after exposure. The yield strength of the steel was exceeded in both cases, cracks and adhesion were studied in depth to characterize their resistance to the simultaneous effect of load and environment. Both coatings offered protection against corrosion; however, localized cracking gave rise to the damage of the substrate. These coatings provided a corrosion barrier, which once damaged is not able of self-healing.
Název v anglickém jazyce
Coatings on Steels T91 and 316L in Lead-Bismuth Eutectic Environment
Popis výsledku anglicky
The work is aimed on the coatings used as a barrier against Heavy Liquid Metal (HLM) influence and coated material behaviour under mechanical loading. The comparison of two kinds of coatings deposited on two different steels is examined: ferritic-martensitic steel T91 coated with AlTiN and austenitic steel 316L coated with Al2O3. Both samples underwent tensile tests with constant extension rate in the HLM autoclave-cell for material testing. The testing environment in the cell was liquid PbBi eutectic at the temperature of 550 °C. The examination by Scanning electron microscopy and Energy-dispersive X-ray spectroscopy followed after exposure. The yield strength of the steel was exceeded in both cases, cracks and adhesion were studied in depth to characterize their resistance to the simultaneous effect of load and environment. Both coatings offered protection against corrosion; however, localized cracking gave rise to the damage of the substrate. These coatings provided a corrosion barrier, which once damaged is not able of self-healing.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering, vol. 461 (2019)
ISBN
—
ISSN
1757-8981
e-ISSN
1757-899X
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IOP Publishing
Místo vydání
—
Místo konání akce
Plzeň
Datum konání akce
14. 11. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—