Replication of gamma-irradiated materials in susen hot cells
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F19%3AN0000188" target="_blank" >RIV/26722445:_____/19:N0000188 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.confer.cz/metal/2019/714-replication-of-gamma-irradiated-materials-in-susen-hot-cells" target="_blank" >https://www.confer.cz/metal/2019/714-replication-of-gamma-irradiated-materials-in-susen-hot-cells</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.37904/metal.2019.714" target="_blank" >10.37904/metal.2019.714</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Replication of gamma-irradiated materials in susen hot cells
Popis výsledku v původním jazyce
The work is designed for the establishment of experimental techniques for replicating of highly-active neutron irradiated samples in SUSEN hot-cells. Using the most sensitive devices for dimensions and defects measurements of irradiated materials is limited due to the negative effect on their operation lifetime and accuracy. Therefore, new replication techniques are needed for the long time operation of the hot cells and its equipment which are sensitive to gamma radiation. The replicas of irradiated material, that are made using manipulators inside the hot-cell, are made of the polymers that are not activated during the operation, so that they can be easily used for the standard measurement procedures. This work describes 3D dimensions measurement and reconstruction of the irradiated materials and evolution of the replication methodology. © 2019 TANGER Ltd., Ostrava.
Název v anglickém jazyce
Replication of gamma-irradiated materials in susen hot cells
Popis výsledku anglicky
The work is designed for the establishment of experimental techniques for replicating of highly-active neutron irradiated samples in SUSEN hot-cells. Using the most sensitive devices for dimensions and defects measurements of irradiated materials is limited due to the negative effect on their operation lifetime and accuracy. Therefore, new replication techniques are needed for the long time operation of the hot cells and its equipment which are sensitive to gamma radiation. The replicas of irradiated material, that are made using manipulators inside the hot-cell, are made of the polymers that are not activated during the operation, so that they can be easily used for the standard measurement procedures. This work describes 3D dimensions measurement and reconstruction of the irradiated materials and evolution of the replication methodology. © 2019 TANGER Ltd., Ostrava.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings 28th International Conference on Metallurgy and Materials
ISBN
978-80-87294-92-5
ISSN
2694-9296
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
—
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
22. 5. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000539487400097