Comparison of Neutron-Gamma Separation Qualities of Various Organic Scintillation Materials and Liquid Scintillator LSB-200
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F21%3AN0000016" target="_blank" >RIV/26722445:_____/21:N0000016 - isvavai.cz</a>
Výsledek na webu
<a href="https://asmedigitalcollection.asme.org/nuclearengineering/article-abstract/7/2/024502/1087949/Comparison-of-Neutron-Gamma-Separation-Qualities?redirectedFrom=fulltext" target="_blank" >https://asmedigitalcollection.asme.org/nuclearengineering/article-abstract/7/2/024502/1087949/Comparison-of-Neutron-Gamma-Separation-Qualities?redirectedFrom=fulltext</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1115/1.4048767" target="_blank" >10.1115/1.4048767</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Neutron-Gamma Separation Qualities of Various Organic Scintillation Materials and Liquid Scintillator LSB-200
Popis výsledku v původním jazyce
In this work, we compare the pulse-shape discrimination (PSD) properties of newly developed liquid scintillator LSB-200, EJ-299-33A, BC-501A, stilbene, p-terphenyl, and Hidex Aqualight in neutron field generated by the LVR-15 reactor with silicon filter utilization. Pulses from the scintillators are processed by the Neutron-Gamma spectrometer. This spectrometric system with fast digitizer card contains two analog-digital converters with a resolution of 12 bits and sampling frequency 500 x 10(6) Hz. For photomultiplier linearity improvement, the active divider has been used. Measured data from scintillators have been processed using the integration method and compared. The results are presented.
Název v anglickém jazyce
Comparison of Neutron-Gamma Separation Qualities of Various Organic Scintillation Materials and Liquid Scintillator LSB-200
Popis výsledku anglicky
In this work, we compare the pulse-shape discrimination (PSD) properties of newly developed liquid scintillator LSB-200, EJ-299-33A, BC-501A, stilbene, p-terphenyl, and Hidex Aqualight in neutron field generated by the LVR-15 reactor with silicon filter utilization. Pulses from the scintillators are processed by the Neutron-Gamma spectrometer. This spectrometric system with fast digitizer card contains two analog-digital converters with a resolution of 12 bits and sampling frequency 500 x 10(6) Hz. For photomultiplier linearity improvement, the active divider has been used. Measured data from scintillators have been processed using the integration method and compared. The results are presented.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1603" target="_blank" >LQ1603: Výzkum pro SUSEN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Nuclear Engineering and Radiation Science
ISSN
2332-8983
e-ISSN
2332-8975
Svazek periodika
7
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
1-6
Kód UT WoS článku
000630005800005
EID výsledku v databázi Scopus
2-s2.0-85096324643