Use of nickel sphere and copper cube with Cf-252 neutron source in the centre for test of nuclear data libraries ENDF/B-VII.1, ENDF/B-VIII.0, JEFF-3.3, BROND-3.1
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F23%3AN0000049" target="_blank" >RIV/26722445:_____/23:N0000049 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.epj-conferences.org/articles/epjconf/abs/2023/10/epjconf_nd2023_15007/epjconf_nd2023_15007.html" target="_blank" >https://www.epj-conferences.org/articles/epjconf/abs/2023/10/epjconf_nd2023_15007/epjconf_nd2023_15007.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/202328415007" target="_blank" >10.1051/epjconf/202328415007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of nickel sphere and copper cube with Cf-252 neutron source in the centre for test of nuclear data libraries ENDF/B-VII.1, ENDF/B-VIII.0, JEFF-3.3, BROND-3.1
Popis výsledku v původním jazyce
The leakage neutron spectrum measurements have been done on benchmark spherical assembly-nickel sphere with a diameter of 50 cm and a copper cube (block) with dimensions of 49.5 x 49.5 x 48 cm(3) in Research Centre Rez (RC Rez). The Cf-252 neutron source was placed into the centre of nickel sphere and copper cube. The proton recoil method was used for the neutron spectrum measurement using spherical hydrogen proportional detectors (HPD) with pressure of 400 and 1000 kPa (diameter of detectors is 4 cm) and scintillation stilbene (ST) detector (diam. of 1 x 1 cm). The neutron energy range of spectrometer is from 0.04 MeV to 1.3 MeV for HPD and from 1 MeV to 12 MeV for ST. The adequate MCNP neutron spectrum calculations based on data libraries ENDF/B-VII.1, ENDF/B-VIII.0, JEFF-3.3, BROND-3.1 were done and compared with the experiment, i.e., calculation to experiment ratio C/E was determined.
Název v anglickém jazyce
Use of nickel sphere and copper cube with Cf-252 neutron source in the centre for test of nuclear data libraries ENDF/B-VII.1, ENDF/B-VIII.0, JEFF-3.3, BROND-3.1
Popis výsledku anglicky
The leakage neutron spectrum measurements have been done on benchmark spherical assembly-nickel sphere with a diameter of 50 cm and a copper cube (block) with dimensions of 49.5 x 49.5 x 48 cm(3) in Research Centre Rez (RC Rez). The Cf-252 neutron source was placed into the centre of nickel sphere and copper cube. The proton recoil method was used for the neutron spectrum measurement using spherical hydrogen proportional detectors (HPD) with pressure of 400 and 1000 kPa (diameter of detectors is 4 cm) and scintillation stilbene (ST) detector (diam. of 1 x 1 cm). The neutron energy range of spectrometer is from 0.04 MeV to 1.3 MeV for HPD and from 1 MeV to 12 MeV for ST. The adequate MCNP neutron spectrum calculations based on data libraries ENDF/B-VII.1, ENDF/B-VIII.0, JEFF-3.3, BROND-3.1 were done and compared with the experiment, i.e., calculation to experiment ratio C/E was determined.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2023041" target="_blank" >LM2023041: České mezinárodní centrum výzkumných reaktorů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
15TH INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, ND2022
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
—
Místo vydání
—
Místo konání akce
online
Datum konání akce
21. 7. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001006475600168