Long term activity measurement of the primary circuit water on the LVR-15 research reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F24%3AN0000024" target="_blank" >RIV/26722445:_____/24:N0000024 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1738573323005272" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1738573323005272</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.net.2023.11.028" target="_blank" >10.1016/j.net.2023.11.028</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long term activity measurement of the primary circuit water on the LVR-15 research reactor
Popis výsledku v původním jazyce
Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.
Název v anglickém jazyce
Long term activity measurement of the primary circuit water on the LVR-15 research reactor
Popis výsledku anglicky
Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Engineering and Technology
ISSN
1738-5733
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
KR - Korejská republika
Počet stran výsledku
4
Strana od-do
1250-1253
Kód UT WoS článku
001226667500001
EID výsledku v databázi Scopus
2-s2.0-85178200401