Measurement of fast neutron spectrum in the radial channel of VR-1 research reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F24%3AN0000026" target="_blank" >RIV/26722445:_____/24:N0000026 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/24:00369033 RIV/00216224:14330/24:00135739
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0969806X23006151" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0969806X23006151</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radphyschem.2023.111369" target="_blank" >10.1016/j.radphyschem.2023.111369</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of fast neutron spectrum in the radial channel of VR-1 research reactor
Popis výsledku v původním jazyce
Having knowledge of the spectrum of fast neutrons in the irradiation position of a reactor plays an important role in many experimental settings. If well described, it can be used as a reference neutron field for validating and testing measuring devices or detectors. This paper compares model calculations with measurements of the neutron spectrum in the research reactor VR-1. The fast neutron spectrum was measured in the radial channel of VR-1 reactor using a stilbene scintillation detector and the NGA-01 measuring device. The NGA-01 is a two-parameter spectrometric system for neutron and gamma radiation fields. The calculations were performed in a critical mode of the MCNP6 code using ENDF/B-VII.1 nuclear data library. Generally, a good agreement was achieved. However, a slight discrepancy in the neutron spectrum between the calculated and measured values was found in the 2–3 MeV region. In other regions, the differences between calculated and experimental values are comparable with uncertainties. Since the detector is distanced from the core, the neutron beam can be assumed parallel and therefore possible issues with stilbene anisotropy are eliminated. Thus, this experiment can be used for validation of a reactor leakage spectrum and nuclear cross sections in the energy region above 6 MeV, which is of interest for the nuclear data section of International Atomic Energy Agency.
Název v anglickém jazyce
Measurement of fast neutron spectrum in the radial channel of VR-1 research reactor
Popis výsledku anglicky
Having knowledge of the spectrum of fast neutrons in the irradiation position of a reactor plays an important role in many experimental settings. If well described, it can be used as a reference neutron field for validating and testing measuring devices or detectors. This paper compares model calculations with measurements of the neutron spectrum in the research reactor VR-1. The fast neutron spectrum was measured in the radial channel of VR-1 reactor using a stilbene scintillation detector and the NGA-01 measuring device. The NGA-01 is a two-parameter spectrometric system for neutron and gamma radiation fields. The calculations were performed in a critical mode of the MCNP6 code using ENDF/B-VII.1 nuclear data library. Generally, a good agreement was achieved. However, a slight discrepancy in the neutron spectrum between the calculated and measured values was found in the 2–3 MeV region. In other regions, the differences between calculated and experimental values are comparable with uncertainties. Since the detector is distanced from the core, the neutron beam can be assumed parallel and therefore possible issues with stilbene anisotropy are eliminated. Thus, this experiment can be used for validation of a reactor leakage spectrum and nuclear cross sections in the energy region above 6 MeV, which is of interest for the nuclear data section of International Atomic Energy Agency.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Physics and Chemistry
ISSN
0969-806X
e-ISSN
—
Svazek periodika
216
Číslo periodika v rámci svazku
March
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
1-5
Kód UT WoS článku
001111321200001
EID výsledku v databázi Scopus
2-s2.0-85176105363