The use of organic material MAKROCLEAR for radiochromic integrating dosimetry of hadron beams
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F25%3AN0000011" target="_blank" >RIV/26722445:_____/25:N0000011 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.rad-proceedings.org/papers/RadProc.2024.07.pdf" target="_blank" >https://www.rad-proceedings.org/papers/RadProc.2024.07.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21175/RadProc.2024.07" target="_blank" >10.21175/RadProc.2024.07</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The use of organic material MAKROCLEAR for radiochromic integrating dosimetry of hadron beams
Popis výsledku v původním jazyce
The Laboratory of Cyclotrons and Fast Neutron Generators performed a series of experimental irradiations of MAKROCLEAR radiochromic integrating dosimeters by proton and deuteron beams accelerated on a U-120M cyclotron. These dosimeters have been developed at the Research Centre Rez. The dosimeters prepared in the form of small blocks were successively irradiated by protons and deuterons of various energies and in various doses. The results of the analyzes showed that MAKROCLEAR dosimeters are very useful as inexpensive and readily available integrating proton dosimeters in the dose range up to about 7.5 kGy, where their response in white light and monochromatic light with longer wavelenght (about 640 nm) is practically linear with a dose. An even higher measuring range was seen in the case of deuterons, where the response of dosimeters was linear with a dose up to 15 kGy.
Název v anglickém jazyce
The use of organic material MAKROCLEAR for radiochromic integrating dosimetry of hadron beams
Popis výsledku anglicky
The Laboratory of Cyclotrons and Fast Neutron Generators performed a series of experimental irradiations of MAKROCLEAR radiochromic integrating dosimeters by proton and deuteron beams accelerated on a U-120M cyclotron. These dosimeters have been developed at the Research Centre Rez. The dosimeters prepared in the form of small blocks were successively irradiated by protons and deuterons of various energies and in various doses. The results of the analyzes showed that MAKROCLEAR dosimeters are very useful as inexpensive and readily available integrating proton dosimeters in the dose range up to about 7.5 kGy, where their response in white light and monochromatic light with longer wavelenght (about 640 nm) is practically linear with a dose. An even higher measuring range was seen in the case of deuterons, where the response of dosimeters was linear with a dose up to 15 kGy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
RAD conference proceedings, vol. 8
ISBN
—
ISSN
—
e-ISSN
2466-4626
Počet stran výsledku
7
Strana od-do
28-34
Název nakladatele
—
Místo vydání
—
Místo konání akce
Herceg Novi, Montenegro
Datum konání akce
17. 6. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—