Biomechanical comparison of screw position in variable angle locking plate in intra-articular calcaneal fractures: Cadaveric and radiologic study.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F27283933%3A_____%2F25%3AN0000033" target="_blank" >RIV/27283933:_____/25:N0000033 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24410/25:00014560 RIV/46747885:24510/25:00014560 RIV/00216208:11130/25:10498054
Výsledek na webu
<a href="https://www.clinbiomech.com/article/S0268-0033(25)00107-X/abstract" target="_blank" >https://www.clinbiomech.com/article/S0268-0033(25)00107-X/abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.clinbiomech.2025.106534." target="_blank" >10.1016/j.clinbiomech.2025.106534.</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical comparison of screw position in variable angle locking plate in intra-articular calcaneal fractures: Cadaveric and radiologic study.
Popis výsledku v původním jazyce
BACKGROUND: Lateral plating of calcaneal fractures using variable-angle locking plates is still the golden standard for severely comminuted cases. The aim of this study is to explore the possibilities of improving stability of osteosynthesis by changing screw directions. It provides an assessment and comparison of cadaveric biomechanical experiment with retrospective radiologic data analysis. METHODS: In the cadaveric study 8 intact calcaneus-talus specimens were obtained from 4 deceased donors. Fracture type 2b according to Sanders' classification was created in each specimen and fixed with variable-angle locking plate. The specimens were divided in 2 groups differing in orientation of anterior screws and fixed in PMMA base. A push-in test was performed by a two-column testing machine until gross failure. Retrospective cohort study was performed, reviewing data of 74 patients which underwent surgical treatment of calcaneal fractures with the same construct. Evaluation was performed at scheduled CT and X-Ray controls. Direction of inserted screws and implant failure were noted. FINDINGS: The cadaveric study proved that there is no significant difference in mean failure force between two abovementioned screw configurations in Sanders 2b fracture. A significant difference was observed in initial stiffness. The radiologic retrospective study showed that difference in screw position within all fracture types but type 2b is significant. INTERPRETATION: Screw configuration in the anterior part of variable-angle locking plate appears to affect primary stiffness and stability of the construct. Particularly in more comminuted fractures, screw inserted in the direction of sustentaculum improves the stability and lowers risk of implant failure.
Název v anglickém jazyce
Biomechanical comparison of screw position in variable angle locking plate in intra-articular calcaneal fractures: Cadaveric and radiologic study.
Popis výsledku anglicky
BACKGROUND: Lateral plating of calcaneal fractures using variable-angle locking plates is still the golden standard for severely comminuted cases. The aim of this study is to explore the possibilities of improving stability of osteosynthesis by changing screw directions. It provides an assessment and comparison of cadaveric biomechanical experiment with retrospective radiologic data analysis. METHODS: In the cadaveric study 8 intact calcaneus-talus specimens were obtained from 4 deceased donors. Fracture type 2b according to Sanders' classification was created in each specimen and fixed with variable-angle locking plate. The specimens were divided in 2 groups differing in orientation of anterior screws and fixed in PMMA base. A push-in test was performed by a two-column testing machine until gross failure. Retrospective cohort study was performed, reviewing data of 74 patients which underwent surgical treatment of calcaneal fractures with the same construct. Evaluation was performed at scheduled CT and X-Ray controls. Direction of inserted screws and implant failure were noted. FINDINGS: The cadaveric study proved that there is no significant difference in mean failure force between two abovementioned screw configurations in Sanders 2b fracture. A significant difference was observed in initial stiffness. The radiologic retrospective study showed that difference in screw position within all fracture types but type 2b is significant. INTERPRETATION: Screw configuration in the anterior part of variable-angle locking plate appears to affect primary stiffness and stability of the construct. Particularly in more comminuted fractures, screw inserted in the direction of sustentaculum improves the stability and lowers risk of implant failure.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30401 - Health-related biotechnology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clin Biomech
ISSN
0268-0033
e-ISSN
1879-1271
Svazek periodika
125
Číslo periodika v rámci svazku
23.4.2025
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
106534
Kód UT WoS článku
001483115900001
EID výsledku v databázi Scopus
2-s2.0-105003132466